English
Language : 

SLIN-12E1AX Datasheet, PDF (20/26 Pages) Bel Fuse Inc. – NON-ISOLATED DC/DC CONVERTERS 4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /12 A Outputs
NON-ISOLATED DC/DC CONVERTERS
4.5 Vdc - 14 Vdc Input, 0.69 Vdc - 5.5 Vdc /12 A Outputs
November 5, 2009
Bel Power, Inc. , a subsidiary of Bel Fuse, Inc.
Tunable LoopTM (Continued)
Table 2.General recommended values of RTUNE and CTUNE for Vin=12V and various external ceramic capacitor
combinations.
Co
RTUNE
CTUNE
1x47μF
470
1000pF
2x47μF
270
3300pF
4x47μF 10x47μF 20x47μF
150
150
150
4700pF 8200pF 12nF
Table 3.Recommended values of RTUNE and CTUNE to obtain transient deviation of ≤2% of Vout for a 6A step load
with Vin=12V.
Vo
Co
RTUNE
CTUNE
ΔV
5V
4x47μF
270
3300pF
91mV
3.3V
2.5V
1x47μF + 330μF 2x47μF + 330μF
Polymer
Polymer
220
220
4700pF
6800pF
60mV
47mV
1.8V
1.2V
0.69V
6x47μF + 330μF 6x47μF + 2x330μF 4x47μF + 6x330μF
Polymer
Polymer
Polymer
220
150
150
18nF
33nF
100nF
35mV
23mV
12mV
Thermal Considerations
Power modules operate in a variety of thermal environments; however, sufficient cooling should always be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow, module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the module will result in an increase in reliability. The
thermal data presented here is based on physical measurements taken in a wind tunnel. The test set-up is
shown below.
Wind Tunnel
25.4_
(1.0)
PWBs
Power Module
76.2_
(3.0)
x
12.7_
(0.50)
Air
flow
Probe Location
for measuring
airflow and
ambient
temperature
Thermal Test Setup
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com