English
Language : 

XRSB-50T03C Datasheet, PDF (12/15 Pages) Bel Fuse Inc. – ISOLATED DC/DC CONVERTERS
ISOLATED DC/DC CONVERTERS
36 Vdc - 75 Vdc Input,
3.3 Vdc/15 A Output
Jul. 09, 2010
Bel Power Inc., a subsidiary of Bel Fuse Inc.
Over Temperature Protection
The OTP is achieved by thermistor U1 and the threshold is set at 120C in non-latch mode; the hottest component
Q5 reaches 130C with 100LFM air flow correspondingly. It will restart automatically when the temperature falls
down to 100C. The protecting point will be varied a little under different conditions (air flow, ambient temperature,
input voltage, load...).
the hottest component Q5 on top view
thermistor U1 on bottom view
Under Voltage Lockout
Under-voltage Lockout
V1
V2
V1=31V
V2=32V
Voltage Falling
Voltage Rising
Input Voltage (V)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
12