English
Language : 

S553-6500-62 Datasheet, PDF (1/2 Pages) Bel Fuse Inc. – HIGH FREQUENCY MAGNETICS
HIGH FREQUENCY MAGNETICS
T1/E1 Dual Interface Transformers
TM00129
• Designed to meet the requirements for UL 1950
reinforced insulation
• Minimum interwinding breakdown voltage of 3000 Vrms
ELECTRICAL SPECIFICATIONS at 25° C
Part Number
Turns Ratio
±5%
Coil A
Coil B
Primary
Inductance*
mH min
Leakage Interwinding
Inductance Capacitance
µH max
pF max
DCR
Ω
max
Coil A & B Coil A & B Coil A & B
Pri
Sec
Coil A Coil B Coil A Coil B
S553-6500-62 1 CT : 2 CT 1 CT : 1 CT
1.5
0.6
15
0.50
0.50
1.00
0.50
S553-6500-63 1 CT : 1.15 CT 1 CT : 1 CT
1.5
0.6
15
1.00
1.00
1.00
1.00
* Measured at 10 kHz, 0.01 Vac
SCHEMATICS
S553-6500-62
S553-6500-63
Primary
1
Coil A 2
3
6
Coil B 7
8
Primary
Secondary
16
15
14
11
10
9
Secondary
Secondary
1
Coil A 2
3
6
Coil B 7
8
Primary
Primary
16
15
14
11
10
9
Secondary
©2000 Bel Fuse Inc. Specifications subject to change without notice. 05.00
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
T1-65