English
Language : 

G2PW1V860 Datasheet, PDF (1/8 Pages) Bel Fuse Inc. – PISCES II DC/DC CONVERTERS
PISCES II DC/DC CONVERTERS
48V Input – 1.8VDC – 60A Output
G2PW1V860 – 1/4 Brick Pisces II Series
• Industry standard pinout and footprint
• Very low dissipation
• No heat sink required for most applications
• Low profile, 0.38"
• High efficiency: 90% at 1.8V, 60A; 91% at 1.8V, 30A
• Very low common-mode noise for a commercial DC/DC converter
• Two-stage input filter
• Constant switching frequency
• Remote sense, wide trim range
• Single board design, very low parts count
• Optional baseplate or low profile heat sink for improved thermal performance
• Header with M3 metal inserts for mechanical connection to PCB
POWER PRODUCTS
G2PW1V860
Control Functions
• Uses patented power supply control and architecture
• Microprocessor controlled
• Primary-side enable, choice of logic
Protection Features
• Over temperature protection
• Over voltage protection
• Over current protection
• Over/Under input voltage protection
Ordering Information
Typical Characteristics
• Output setpoint accuracy: ± 1%
• Load regulation: ± 0.2%
• Line regulation: ± 0.2%
• Regulation over line, load,
and temperature: ± 2%
• Low output ripple
• Output trim
Example Part Number: (All options)
G2PW1V860 PS RT 0 0 X
Standard Model Number Input Voltage Output Voltage Max Current
G2PW1V860*
48V
1.8V
60A
* Options:
P = Positive Logic Version;
High = On
E = 0.18" Pins (± .01") R = Heat Sink Ready
M = 0.145" Pins (± .01") T = Tuned model**
S = 0.12" Pins (± .01")
Pisces II Heat Sink
Part Numbers
Typical Thermal Performance
Part Number
Options:
Positive Logic Version
Optional Pin Lengths
E = 0.18"
M = 0.145"
S = 0.12"
Heat Sink Ready
Tuned Model
Heat Sink
Part
Number
Height
Natural Convection Forced Convection
Power Dissipation† Thermal Resistance‡
001
0.25"
002
0.50"
003
1.00"
004
0.13"
5W
7W
11W
TBD
5.8˚ C/W
3.2˚ C/W
2.0˚ C/W
TBD
005
0.70"
TBD
TBD
† @ 60˚ C rise heat sink to ambient
‡ @ 300'/min.
** T (Tuned Model) Option
Designed for higher di/dt and ∆l
applications, the transient response has
been modified to take advantage of the
capacitance on the customer’s PCB. This
unit requires a minimum load capacitance
of 5600µF with an impedance magnitude
of less than 0.005Ω at 15kHz. It offers
a minmum 3X improvement in the peak
response compared to a standard unit.
Consult factory.
©2006 Bel Fuse Inc. Specifications subject to change without notice. 11.06
Bel Power Inc. 155 Flanders Road, Westborough, MA 01581 • Tel 508-870-9775 • Fax 508-870-9796 • www.belpower.com