|
2664AM Datasheet, PDF (1/2 Pages) Bel Fuse Inc. – HIGH FREQUENCY MAGNETICS T1/E1 Single THT Shielded Hardened Transformer | |||
|
HIGH FREQUENCY MAGNETICS
T1/E1 Single THT Shielded Hardened Transformer
TM00122
⢠Designed for T1 carrier applications at 1.544 Mbps
⢠Typical application is to isolate telecom equipment
such as CSUs and office repeaters from the T1line
⢠Compatible with water-soluble flux, total-immersion
cleaning, and machine insertion
⢠Shielded transformer reduces EMI
⢠Maximum ac current rating is 140mA for winding (6 - 7) ⢠Designed for 100⦠terminating impedances
and 280mA for winding (4 - 1)
⢠Minimum interwinding breakdown voltage of 1000 Vrms
⢠Winding (4 - 1) is hardened to handle 6 amp current for
one second with no damage
⢠Meets IEC-695, 2-2 flammability requirements
⢠Qualified per Bellcore TR-TSY-000357-1
ELECTRICAL SPECIFICATIONS at 25° C
Part Number
2664AM
Turns Ratio
± 2%
Pri : Sec
1 : 1 CT
Primary
Inductance*
mH min
1.5
* Measured at 10 kHz, 0.1 Vac
Leakage
Inductance
µH max
3.5
DCR
â¦
max
Pri
Sec
1.0
0.5
Interwinding
Capacitance
pFmax
5 with terminal 5
grounded
SCHEMATIC
2664AM
S
6
4
2
CT
3
7
1
Primary 5 Secondary
Note: Noise suppression is improved by connecting
the shield, terminal 5, to equipment frame ground.
©2000 Bel Fuse Inc. Specifications subject to change without notice. 09.00
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 ⢠Tel 201-432-0463 ⢠Fax 201-432-9542 ⢠www.belfuse.com
T1-49
|
▷ |