2664AM Datasheet, PDF (1/2 Pages) Bel Fuse Inc. – HIGH FREQUENCY MAGNETICS T1/E1 Single THT Shielded Hardened Transformer
HIGH FREQUENCY MAGNETICS
T1/E1 Single THT Shielded Hardened Transformer
TM00122
• Designed for T1 carrier applications at 1.544 Mbps
• Typical application is to isolate telecom equipment
such as CSUs and office repeaters from the T1line
• Compatible with water-soluble flux, total-immersion
cleaning, and machine insertion
• Shielded transformer reduces EMI
• Maximum ac current rating is 140mA for winding (6 - 7) • Designed for 100Ω terminating impedances
and 280mA for winding (4 - 1)
• Minimum interwinding breakdown voltage of 1000 Vrms
• Winding (4 - 1) is hardened to handle 6 amp current for
one second with no damage
• Meets IEC-695, 2-2 flammability requirements
• Qualified per Bellcore TR-TSY-000357-1
ELECTRICAL SPECIFICATIONS at 25° C
Part Number
2664AM
Turns Ratio
± 2%
Pri : Sec
1 : 1 CT
Primary
Inductance*
mH min
1.5
* Measured at 10 kHz, 0.1 Vac
Leakage
Inductance
µH max
3.5
DCR
Ω
max
Pri
Sec
1.0
0.5
Interwinding
Capacitance
pFmax
5 with terminal 5
grounded
SCHEMATIC
2664AM
S
6
4
2
CT
3
7
1
Primary 5 Secondary
Note: Noise suppression is improved by connecting
the shield, terminal 5, to equipment frame ground.
©2000 Bel Fuse Inc. Specifications subject to change without notice. 09.00
Bel Fuse Inc. 198 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com