English
Language : 

0RQB-C5T_SERIES Datasheet, PDF (1/12 Pages) Bel Fuse Inc. – ISOLATED DC/DC CONVERTERS
ISOLATED DC/DC CONVERTERS
48 Vdc Input 12 Vdc/12 A, 3.3 Vdc/46 A, 5 Vdc/30 A, 1.2-2.5 Vdc/50 A Outputs
0RQB-C5T Series
RoHS Compliant
Rev.B
• Isolated
• Output Over Voltage Shutdown
• High Efficiency
• OCP/SCP
• High Power Density
• Over Temperature Protection
• Low Cost
• Remote On/Off
• Input Under Voltage Lockout
• Output Voltage Trim
• Fixed Frequency (330 kHz)
• Positive/Negative Remote Sense
• Active Low/High (Option)
• Input Over Voltage Lockout
• UL60950-1 Recognized (UL/cUL) • Basic Isolation
Description
The 0RQB-C5T Series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units will
provide up to 150 W of output power from a nominal 48 Vdc input. These units are designed to be highly efficient
and low cost. Typical efficiency of 12 Vdc output at 48 Vdc input at full load is 93%. Features include remote
on/off, over current protection and under-voltage lockout. These converters are provided in an industry standard
quarter brick package.
Part Selection
Output
Voltage
Input
Voltage
12 V
36 V - 75 V
Max. Output
Current
12 A
Max. Output
Power
144 W
Typical
Efficiency
93.0%
Model Number
Active High
0RQB-C5T120
Model Number
Active Low
0RQB-C5T12L
5.0 V
36 V - 75 V
30 A
150 W
92.5%
0RQB-C5T050
0RQB-C5T05L
3.3 V
36 V - 75 V
46 A
152 W
91.0%
0RQB-C5T033
0RQB-C5T03L
2.5 V
36 V - 75 V
50 A
125 W
90.5%
0RQB-C5T025
0RQB-C5T02L
1.8 V
36 V - 75 V
50 A
90 W
88.0%
0RQB-C5TV80
0RQB-C5TV8L
1.5 V
36 V - 75 V
50 A
75 W
85.0%
0RQB-C5TV50
0RQB-C5TV5L
1.2 V
36 V - 75 V
50 A
60 W
83.0%
0RQB-C5TV20
0RQB-C5TV2L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Input Voltage (continuous)
-0.3 V
-
80 V
Remote On/Off
-0.3 V
-
18 V
I/O Isolation Voltage
-
-
2000 V
Ambient Temperature
-40 °C
-
85 °C
Storage Temperature
-55 °C
-
125 °C
Note: All specifications are typical at nominal input, full load at 25 °C unless noted.
Notes
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com