English
Language : 

0RLC-25T Datasheet, PDF (1/10 Pages) Bel Fuse Inc. – ISOLATED DC/DC CONVERTERS
ISOLATED DC/DC CONVERTERS
48 Vdc Input 3.3 Vdc - 24 Vdc/7 A - 1.25 A Output
0RLC-25T Series RoHS Compliant Rev.A
• Fixed Frequency (230 kHz)
• Output Over Voltage Shut Down
• Isolated
• High Efficiency
• High Power Density
• Low Cost
• Safety Approval to UL60950-1
(Pending)
• Remote On/Off
• Output Voltage Trim
• Input Under Voltage Lockout
• SCP/OCP
• Over Temperature Protection
• Remote On/Off Logic (Option)
Description
The 0RLC-25T series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units will
provide up to 30 W of output power. These units are designed to be high efficient and very low cost. Features
include remote on/off, over current protection, and under voltage lockout. These converters are provided in an
industry standard package.
Part Selection
Output
Input Voltage
Voltage
3.3 Vdc 36 Vdc - 75 Vdc
5.0 Vdc 36 Vdc - 75 Vdc
12.0 Vdc 36 Vdc - 75 Vdc
15.0 Vdc 36 Vdc - 75 Vdc
24.0 Vdc 36 Vdc - 75 Vdc
Max. Output
Current
7A
5A
2.5 A
2.0 A
1.25 A
Max. Output
Power
23 W
25 W
30 W
30 W
30 W
Typical
Efficiency
88%
90%
90%
90%
91%
Model Number
Active High
0RLC-25T033
0RLC-25T050
0RLC-25T120
0RLC-25T150
0RLC-25T240
Model Number
Active Low
0RLC-25T03L
0RLC-25T05L
0RLC-25T12L
0RLC-25T15L
0RLC-25T24L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Input Voltage (continuous)
-0.3 V
-
Remote On/Off
-0.3 V
-
Ambient Temperature
-40 °C
-
Storage Temperature
-55 °C
-
Max
80 V
12 V
85 °C
125 °C
Notes
100 V for 100 mS Max
Input Specifications
Parameter
Input Voltage
Input Current
Input Current (no load)
Remote Off Input Current
Min
36 V
-
-
-
Typ
-
-
25 mA
3 mA
Max
75 V
1.1 A
40 mA
10 mA
Input Reflected Ripple Current
(rms)
-
10 mA
20 mA
Input Reflected Ripple Current
(pk-pk)
I2t Inrush Current Transient
Turn-on Input Voltage
Turn-off Input Voltage
-
-
31 V
30 V
40 mA
0.012 A2s
34 V
33 V
60 mA
0.024 A2s
36 V
35 V
Note: All specifications are typical at 25 °C unless otherwise stated.
Notes
With simulated source impedance of 10
uH, 5 Hz to 20 MHz. And use a 100 uF/
100 V electrolytic capacitor with ESR=1
ohm max, at 200 kHz.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com