English
Language : 

0RCR-40S10X Datasheet, PDF (1/7 Pages) Bel Fuse Inc. – ISOLATED DC/DC CONVERTERS
ISOLATED DC/DC CONVERTERS
48 VDC Input 9.6 VDC/40 A Output, 1/8 Brick
0RCR-40S10x RoHS Compliant Rev.E
• Isolated
• Fixed Frequency
• High Efficiency
• High Power Density
• Low Cost
• Input Under-Voltage Lockout
• Input Over-Voltage Shutdown
• OCP/SCP
• Remote On/Off
• Over Temperature Protection
Description
The 0RCR-40S10x Series are isolated DC/DC converters that operate from a nominal 48 VDC source. These
converters use a full bridge power train to provide isolation and step down. These units will provide up to 300 W
of output power from a nominal 48 VDC input. These units are designed to be highly efficient and low cost.
Features include remote on/off, over current protection and under voltage lockout. These converters are provided
in an industry standard eighth-brick package.
Part Selection
Output
Voltage
Input
Voltage
9.6 V
48 V
Max. Output
Current
40 A
Max. Output
Power
300 W
Typical
Efficiency
96.5%
Model Number
Active Low
0RCR-40S10L
Model Number
Active High
0RCR-40S100
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Input Voltage (continuous)
-0.3 V
-
60 V
Remote On/Off (Active Low)
-0.3 V
-
0.8 V
Remote On/Off (Active High)
2.4 V
-
18 V
Ambient Temperature
-40 °C
-
85 °C
Storage Temperature
-40 °C
-
125 °C
Notes
Input Specifications
Parameter
Input Voltage
Input Current (full load)
Input Current (no load)
Remote Off Input Current
Input Reflected Ripple Current (pk-pk)
Min
38 V
-
-
-
-
Typ
-
-
-
-
20 mA
Max
55 V
8.8 A
150 mA
30 mA
50 mA
Input Reflected Ripple Current (rms)
-
5 mA
20 mA
I2t Inrush Current Transient
-
0.05 A2s
0.1 A2s
Turn On Voltage Threshold
34 V
35.5 V
37 V
Turn Off Voltage Threshold
32 V
33.5 V
35 V
Input Over-Voltage Lockout
56 V
58 V
60 V
Note: All specifications are typical at 25 °C unless otherwise stated.
Notes
Tested with simulated source
impedance of 10 uH, 5 Hz to 20 MHz;
use a 100 uF/100 V electrolytic cap
with ESR=1 ohm, at 200kHz at the
input.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com