English
Language : 

0RCR-15T08X Datasheet, PDF (1/5 Pages) Bel Fuse Inc. – ISOLATED DC/DC CONVERTERS
ISOLATED DC/DC CONVERTERS
48 VDC Input 8 VDC/15 A Output, 1/8 Brick
0RCR-15T Series RoHS Compliant Rev.B
• Isolated
• High Efficiency
• High Power Density
• Fixed Frequency
• Remote On/Off
• Input Under Voltage Lockout
• Output Overvoltage Shutdown
• OCP/SCP
• Low Cost
• Thermal Shutdown
Description
The 0RCR-15T Series are isolated DC/DC converters that operate from a nominal 48 VDC source. These
converters use a half bridge power train to provide isolation and step down. These units will provide up to 130 W
of output power from a nominal 48 VDC input. These units are designed to be highly efficient and low cost.
Features include remote on/off, over current protection and under voltage lockout. These converters are provided
in an industry standard eighth-brick package.
Part Selection
Output
Voltage
Input
Voltage
8V
36 V-75 V
Max. Output
Current
15 A
Max. Output
Power
130 W
Typical
Efficiency
95%
Model Number
Active High
0RCR-15T08H
Model Number
Active Low
0RCR-15T08L
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Input Voltage (continuous)
-0.3 V
-
100 V
Remote On/Off
-0.3 V
-
100 V
Ambient Temperature
-40 °C
-
85 °C
Storage Temperature
-40 °C
-
125 °C
Notes
Input Specifications
Parameter
Min
Input Voltage
36 V
Input Current (full load)
-
Input Current (no load)
-
Remote Off Input Current
-
Input Reflected Ripple Current (pk-pk)
-
Typ
-
-
-
2 mA
-
Max
75 V
3A
45 mA
3 mA
N/A
Input Reflected Ripple Current (rms)
-
-
N/A
I2t Inrush Current Transient
Turn On Voltage Threshold
Turn Off Voltage Threshold
-
0.039 A2s 0.062 A2s
-
34.5 V
-
-
32.5 V
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Notes
with simulated source impedance of 10
uH, 5 Hz to 20 MHz; use a 47 uF /100
V electrolytic capacitor with ESR = 1
ohm max. at 200 kHz at 25°C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com