English
Language : 

HR6-12 Datasheet, PDF (1/1 Pages) B. B. Battery Co., Ltd. – VRLA Rechargeable Battery
VRLA Rechargeable Battery
HR6-12 (HR6-12FR)
Measures
Technology
Values
Innovation
FEATURES
APPLICATION
Maintenance free(no water topping-up required)
No free acid(Non-spillable battery)
Low self-discharge rate, lower than 3% capacity
loss per month
Can be used in any orientation(excluding used inverted)
The battery is designed for high rate usage
The power density at 5 min~15min discharging
rate is 30% higher than BP series
UPS
Toy-Cars
Power Packs
Laboratory Equipment
Fishing Lights
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
Operating Temperature Range
Container Material
12 V
5.5Ah @ 10 hour rate F.V.(1.75V/cell)
2100g(4.63lbs.)
T1 (Faston Tab 187) T2 is optional
22m (Fully Charged )
82.5 A (5 sec.)
1.65 A
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
ABS(UL94-HB, UL94-V0 is optional)
DIMENSION(mm/inch)
OUTER DIMENSIONS
ISO 9001
ISO14001
UL
CE
IEC61056
JIS C 8702
GB/T 19639
TERMINAL TYPE
Length
151±1.5 (5.94±0.06)
Width
51±1.5 (2.01±0.06)
Container Height
94±1.5 (3.70±0.06)
Total Height
100±2.0 (3.94±0.08)
151 1.5(5.94 0.06)
511.5(2 .01 0.06)
Terminal T1
3.2(0.13)
Terminal T2
3.4(0.13)
6.35(0.25)
7.85(0.31)
Constant power discharge characteristics at 25 oC/77 oF
Unit: W
Discharge
F.V.
Time
(V/cell)
1.80V
5 Min
246.0
10 Min
168.0
15 Min
121.7
20 Min
103.8
30 Min
78.9
40 Min
60.0
1.70V
294.0
187.5
132.3
109.9
82.2
62.3
1.60V
315.0
197.3
138.3
114.0
84.0
63.7
1.50V
324.0
201.0
141.3
115.8
85.1
64.5
1.40V
330.0
203.7
142.9
116.9
85.7
64.9
1.30V
333.0
205.5
144.0
117.6
86.1
65.3
Constant current discharge characteristics at 25 oC/77 oF Unit: AW
Discharge
F.V.
Time
(V/cell)
1.80V
5 Min
21.96
10 Min
14.74
15 Min
10.53
20 Min
8.90
30 Min
6.69
40 Min
5.05
1.70V
26.73
16.45
11.44
9.43
6.97
5.24
1.60V
28.64
17.31
11.96
9.78
7.12
5.36
1.50V
29.45
17.63
12.22
9.93
7.21
5.42
1.40V
30.00
17.87
12.36
10.03
7.26
5.46
1.30V
30.27
18.03
12.46
10.09
7.30
5.49
All data shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
50 Min
50.1
51.7
52.8
53.4
53.9
54.1
50 Min
4.19
4.33
4.42
4.47
4.51
4.53
60 Min
44.1
45.1
45.9
46.3
46.7
46.8
120 Min
24.3
24.8
25.2
25.3
25.4
25.5
60 Min
3.68
3.76
3.83
3.86
3.89
3.90
120 Min
2.03
2.07
2.10
2.11
2.12
2.13
A/0 REV. Jul. 2009