English
Language : 

BP12-12-T2 Datasheet, PDF (1/1 Pages) B. B. Battery Co., Ltd. – VRLA Rechargeable Battery
VRLA Rechargeable Battery
BP12-12
Measures
Technology
Values
Innovation
FEATURES
APPLICATION
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
Absorbent Glass Mat technology for efficient gas recombination.
UPS
Fishing Lights
Toy-Cars
Power Packs
Laboratory Equipment
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
Operating Temperature Range
Container Material
DIMENSION(mm/inch)
Length
151±1.5 (5.94±0.06)
Width
98±1.5 (3.86±0.06)
Container Height
94±1.5 (3.70±0.06)
Total Height
98±2.0 (3.86±0.08)
12 V
12.0Ah @ 20 hour rate F.V.(1.75V/cell)
3940g(8.69lbs.)
T2 (Faston Tab 250) T1 is optional
18m (Fully Charged )
180 A (5 sec.)
3.6 A
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
Standard: ABS( UL 94-HB) BP12-12
Optional: Flame Retardant ABS(UL 94-V0) BP12-12FR
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
VdS G102106
OUTER DIMENSIONS
TERMINAL TYPE
Terminal T1
3.2(0.13)
Terminal T2
3.4(0.13)
151 1.5(5.94 0.06) 98 1.5(3.86 0.06)
6.35(0.25)
7.95(0.31)
Constant power discharge characteristics at 25 oC/77 oF Unit: W
Discharge
F.V.
(V/cell)
Time
1.80V
5 Min
433.9
10 Min
319.4
15 Min
256.0
30 Min
152.3
1 Hr
87.3
3 Hr
35.0
1.75V
502.2
346.0
267.7
158.1
90.0
35.7
1.70V
533.6
358.5
276.0
161.7
91.6
36.0
1.65V
557.5
367.1
282.4
164.0
92.7
36.3
1.60V
576.0
374.4
288.0
165.6
93.6
36.5
Constant current discharge characteristics at 25 oC/77 oF Unit: A
Discharge
F.V.
(V/cell)
Time
1.80V
5 Min
39.09
10 Min
28.12
15 Min
22.26
30 Min
12.91
1 Hr
7.34
3 Hr
2.91
1.75V
46.07
30.46
23.28
13.40
7.56
2.97
1.70V
48.95
31.55
24.00
13.70
7.70
3.00
1.65V
51.15
32.31
24.55
13.89
7.79
3.02
1.60V
52.84
32.96
25.04
14.03
7.87
3.04
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
5 Hr
24.1
24.5
24.6
24.7
24.8
5 Hr
2.01
2.04
2.05
2.06
2.06
10 Hr
13.48
13.68
13.75
13.79
13.79
20 Hr
7.09
7.20
7.24
7.26
7.26
10 Hr
1.123
1.140
1.146
1.149
1.149
20 Hr
0.591
0.600
0.603
0.605
0.605
A/2 REV. Mar. 2013
Powered by B.B. Battery Co., Ltd.