English
Language : 

BP1.2-12-T1 Datasheet, PDF (1/1 Pages) B. B. Battery Co., Ltd. – VRLA Rechargeable Battery
VRLA Rechargeable Battery
BP1.2-12
Measures
Technology
Values
Innovation
FEATURES
APPLICATION
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
Absorbent Glass Mat technology for efficient gas recombination.
UPS
Security Alarm Systems
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
Operating Temperature Range
Container Material
DIMENSION(mm/inch)
Length
97±1.5 (3.82±0.06)
Width
45±1.5 (1.77±0.06)
Container Height
53±1.5 (2.09±0.06)
Total Height
59±2.0 (2.32±0.08)
12 V
1.20Ah @ 20 hour rate F.V.(1.75V/cell)
590g(1.30lbs.)
T1 (Faston Tab 187)
100m (Fully Charged )
18 A (5 sec.)
0.36 A
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
Standard: ABS( UL 94-HB) BP1.2-12
Optional: Flame Retardant ABS(UL 94-V0) BP1.2-12FR
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
VdS G103041
OUTER DIMENSIONS
TERMINAL TYPE
97 1.5 (3.82 0.06)
45 1.5 (1.77 0.06)
Terminal T1
3.2(0.13)
6.35(0.25)
Constant power discharge characteristics at 25 oC/77 oF Unit: W
Discharge
F.V.
(V/cell)
Time
1.80V
5 Min
43.39
10 Min
31.94
15 Min
25.60
30 Min
15.23
1 Hr
8.73
3 Hr
3.50
5 Hr
2.412
1.75V
50.22
34.60
26.77
15.81
9.00
3.57
2.448
1.70V
53.36
35.85
27.60
16.17
9.16
3.60
2.461
1.65V
55.75
36.71
28.24
16.40
9.27
3.63
2.470
1.60V
57.60
37.44
28.80
16.56
9.36
3.65
2.477
Constant current discharge characteristics at 25 oC/77 oF Unit: A
Discharge
F.V.
Time
(V/cell)
5 Min
10 Min
15 Min
30 Min
1 Hr
3 Hr
5 Hr
1.80V
3.91
2.81
2.23
1.291
0.734
0.291
0.201
1.75V
4.61
3.05
2.33
1.340
0.756
0.297
0.204
1.70V
4.89
3.16
2.40
1.370
0.770
0.300
0.205
1.65V
5.11
3.23
2.46
1.389
0.779
0.302
0.206
1.60V
5.28
3.30
2.50
1.403
0.787
0.304
0.206
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
10 Hr
1.348
1.368
1.375
1.379
1.379
20 Hr
0.709
0.720
0.720
0.720
0.720
10 Hr
0.112
0.114
0.115
0.115
0.115
20 Hr
0.059
0.060
0.060
0.060
0.060
A/2 REV. Mar. 2013
Powered by B.B. Battery Co., Ltd.