English
Language : 

AZP96 Datasheet, PDF (3/6 Pages) Arizona Microtek, Inc – ECL/PECL Differential Receiver
AZP96
AC Characteristics (VEE = -3.0V to -5.5V; VCC = GND or VEE = GND; VCC = +3.0V to +5.5V)
Symbol
Characteristic
-40°C
0°C
25°C
85°C
Unit
Min Typ Max Min Typ Max Min Typ Max Min Typ Max
tPLH / tPHL
Propagation Delay
to Output
(Diff)
125 250 375 175 250 325 175 250 325 205 280 355
ps
(SE)
75 250 425 125 250 375 125 250 375 155 280 405
tSKEW
Duty Cycle Skew 1(Diff)
5
5
20
5
20
5
20
ps
VPP (AC) Minimum Input Swing2
150
150
150
150
mV
Common Mode Range3
VEE +
VCC - VEE +
VCC - VEE +
VCC - VEE +
VCC -
VCMR
VPP < 500mV 1.2
0.4 1.1
0.4 1.1
0.4 1.1
0.4
V
VPP ≥ 500mV 1.5
0.4 1.4
0.4 1.4
0.4 1.4
0.4
tr / tf
Output Rise/Fall Times Q
(20% - 80%)
100
260 100
260 100
260 100
260
ps
1. Duty cycle skew is the difference between a tPLH and tPHL propagation delay through a device.
2. VPP is the minimum peak-to-peak differential input swing for which AC parameters are guaranteed. The device has a DC gain of ≈ 40.
3. The VCMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within
the specified range and the peak-to-peak voltage lies between VPP(min) and 1V.
April 2007 * REV 1
www.azmicrotek.com
3