AZPRD Datasheet, PDF (2/3 Pages) American Zettler, Inc. – SPST, DPST, SPDT, and DPDT versions available | |||
|
◁ |
AZPRD
RELAY ORDERING DATA
Nominal Coil
VDC
6
12
24
48
110
Nominal Coil
VAC
6
12
24
120
240
480
COIL SPECIFICATIONS â DC Coil
Must Operate
VDC
Max. Continuous
VDC
4.50
7.8
9.1
15.4
18.0
32.0
36.0
62.6
82.5
143.0
COIL SPECIFICATIONS â AC Coil 50/60 Hz
Must Operate
VAC
Max. Continuous
VAC
5.1
6.9
10.2
13.8
20.4
27.6
102.0
138.0
204.0
276.0
408.0
552.0
Nominal Current
mA ± 10%
333
166
83
42
18.2
Nominal Coil
Power VA
9.5
9.5
9.5
9.5
9.5
9.5
Coil Resistance
± 10%
18
72
290
1150
6050
Coil Resistance
± 10%
0.85
2.85
11.5
295.0
1170.0
4860.0
ORDER NUMBER*
AZPRDâ1Câ6D
AZPRDâ1Câ12D
AZPRDâ1Câ24D
AZPRDâ1Câ48D
AZPRDâ1Câ110D
ORDER NUMBER*
AZPRDâ1Câ6A
AZPRDâ1Câ12A
AZPRDâ1Câ24A
AZPRDâ1Câ120A
AZPRDâ1Câ240A
AZPRDâ1Câ480A
*For double pole version replace â-1Câ with â-2Câ, â-2Aâ, or â-2Bâ. For SPST replace â-1Câ with â-1Aâ or â-1Bâ. For SPST-NO-DM replace â-1Câ with â-1Xâ(Short
Base). For SPST-NC-DB replace â-1Câ with â-1Yâ(Long Base). For addition of SPDT Auxiliary Snap Switch Rated at 10A and 1/4 H.P. add âSâ after PRD. For
Q.C. 0.250â terminals add âQâ after PRD. For blow out magnets used in high dc loads add âDâ after PRD. For 50A rating with box lug termination add âEâ after
PRD. For 50A rating with screw termination add âRâ after PRD.
4/29/09w
|
▷ |