English
Language : 

AZPRD Datasheet, PDF (2/3 Pages) American Zettler, Inc. – SPST, DPST, SPDT, and DPDT versions available
AZPRD
RELAY ORDERING DATA
Nominal Coil
VDC
6
12
24
48
110
Nominal Coil
VAC
6
12
24
120
240
480
COIL SPECIFICATIONS – DC Coil
Must Operate
VDC
Max. Continuous
VDC
4.50
7.8
9.1
15.4
18.0
32.0
36.0
62.6
82.5
143.0
COIL SPECIFICATIONS – AC Coil 50/60 Hz
Must Operate
VAC
Max. Continuous
VAC
5.1
6.9
10.2
13.8
20.4
27.6
102.0
138.0
204.0
276.0
408.0
552.0
Nominal Current
mA ± 10%
333
166
83
42
18.2
Nominal Coil
Power VA
9.5
9.5
9.5
9.5
9.5
9.5
Coil Resistance
± 10%
18
72
290
1150
6050
Coil Resistance
± 10%
0.85
2.85
11.5
295.0
1170.0
4860.0
ORDER NUMBER*
AZPRD–1C–6D
AZPRD–1C–12D
AZPRD–1C–24D
AZPRD–1C–48D
AZPRD–1C–110D
ORDER NUMBER*
AZPRD–1C–6A
AZPRD–1C–12A
AZPRD–1C–24A
AZPRD–1C–120A
AZPRD–1C–240A
AZPRD–1C–480A
*For double pole version replace “-1C” with “-2C”, “-2A”, or “-2B”. For SPST replace “-1C” with “-1A” or “-1B”. For SPST-NO-DM replace “-1C” with “-1X”(Short
Base). For SPST-NC-DB replace “-1C” with “-1Y”(Long Base). For addition of SPDT Auxiliary Snap Switch Rated at 10A and 1/4 H.P. add “S” after PRD. For
Q.C. 0.250” terminals add “Q” after PRD. For blow out magnets used in high dc loads add “D” after PRD. For 50A rating with box lug termination add “E” after
PRD. For 50A rating with screw termination add “R” after PRD.
4/29/09w