AZ941 Datasheet, PDF (2/2 Pages) List of Unclassifed Manufacturers – MINIATURE PC BOARD RELAY | |||
|
◁ |
AZ941
RELAY ORDERING DATA
STANDARD RELAYS: Light Duty Type (3 Amp Contact)
Nominal Coil
VDC
5
COIL SPECIFICATIONS
Max. Continuous
VDC
Coil Resistance
±10%
9.9
70
6
11.8
100
12
23.6
400
24
47.3
1,600
48
94.6
6,400
STANDARD RELAYS: Medium Duty Type (5 Amp Contact)
Nominal Coil
VDC
5
COIL SPECIFICATIONS
Max. Continuous
VDC
Coil Resistance
±10%
9.9
70
6
11.8
100
12
23.6
400
24
47.3
1,600
48
94.6
6,400
STANDARD RELAYS: Heavy Duty Type (16 Amp Contact)
Nominal Coil
VDC
5
COIL SPECIFICATIONS
Max. Continuous
VDC
Coil Resistance
±10%
9.9
70
6
11.8
100
9
17.7
225
12
23.6
400
24
47.3
1,600
48
94.6
6,400
STANDARD RELAYS: Extra Heavy Duty Type (16 Amp Contact)
Nominal Coil
VDC
5
COIL SPECIFICATIONS
Max. Continuous
VDC
Coil Resistance
±10%
10.9
70
6
13.0
100
12
26.0
400
24
52.1
1,600
48
104.3
*Add suffix âFâ in place of âBâ to indicate class F.
6,400
MECHANICAL DATA
Must Operate
VDC
4.0
4.8
9.6
19.2
38.4
Must Operate
VDC
4.0
4.8
9.6
19.2
38.4
Must Operate
VDC
4.0
4.8
7.2
9.6
19.2
38.4
Must Operate
VDC
4.0
4.8
9.6
19.2
38.4
ORDER NUMBER
Unsealed
Sealed
AZ941â1Câ5D
AZ941â1Câ6D
AZ941â1Câ12D
AZ941â1Câ24D
AZ941â1Câ48D
AZ941â1Câ5DE
AZ941â1Câ6DE
AZ941â1Câ12DE
AZ941â1Câ24DE
AZ941â1Câ48DE
ORDER NUMBER
Unsealed
Sealed
AZ941â1CHâ5D
AZ941â1CHâ6D
AZ941â1CHâ12D
AZ941â1CHâ24D
AZ941â1CHâ48D
AZ941â1CHâ5DE
AZ941â1CHâ6DE
AZ941â1CHâ12DE
AZ941â1CHâ24DE
AZ941â1CHâ48DE
ORDER NUMBER
Unsealed
Sealed
AZ941â1CTâ5D
AZ941â1CTâ6D
AZ941â1CTâ9D
AZ941â1CTâ12D
AZ941â1CTâ24D
AZ941â1CTâ48D
AZ941â1CTâ5DE
AZ941â1CTâ6DE
AZ941â1CTâ9DE
AZ941â1CTâ12DE
AZ941â1CTâ24DE
AZ941â1CTâ48DE
ORDER NUMBER*
Unsealed
Sealed
AZ941â1CWâ5DB
AZ941â1CWâ6DB
AZ941â1CWâ12DB
AZ941â1CWâ24DB
AZ941â1CWâ48DB
AZ941â1CWâ5DEB
AZ941â1CWâ6DEB
AZ941â1CWâ12DEB
AZ941â1CWâ24DEB
AZ941â1CWâ48DEB
.89
(22.5)
.65
(16.5)
.01
(0.3)
.01
(0.3)
.65
(16.5)
.040
(1.0)
5 PLACES
.138
(3.5)
PC BOARD LAYOUT
.082
(2.1)
.05 5 HOLES
(1.3)
.089
(2.3)
.472
(12.0)
.078
(2.0)
.480
(12.2)
.089
(2.3)
Viewed toward terminals
WIRING DIAGRAM
2
3
1
5
4
Viewed toward terminals
Dimensions in inches with metric equivalents in parentheses. Tolerance: ±0.010"
8/7/03W
|