English
Language : 

AZ8512 Datasheet, PDF (1/4 Pages) American Zettler, Inc. – Microminiature size: Height: .212 inches (5.4 mm)
AZ8512
MICROMINIATURE
POLARIZED RELAY
FEATURES
• Microminiature size: Height: .212 inches (5.4 mm);
Length: .551 inches (14.0 mm);
Width: .354 inches (9.0 mm)
• Low power consumption
• Meets FCC Part 68.302 1500 V lightning surge
• Surface mount type with “L” shaped terminals
• Single side stable and latching available
• UL, CUR file E43203
CONTACTS
Arrangement
Ratings
DPDT (2 Form C)
Resistive load:
Max. switched power: 30 W or 62.5 VA
Max. switched current: 2A
Max. switched voltage: 110 VDC or 125 VAC
Rated Load
UL
Material
Resistance
2 A at 30 VDC resistive (100K cycles, 40°C)
1 A at 30 VDC resistive (200K cycles, 70°C)
0.5 A at 125 VAC resistive (100K cycles, 70°C)
AgNi + Au plated
< 100 milliohms initially
COIL (Polarized)
Power
At Pickup Voltage
(typical)
79mW Single Side Stable
56mW 1 Coil Latching
113mW 2 Coils Latching
Temperature
Max. 105°C (221°F)
NOTES
1. All values at 20°C (68°F).
2. Relay has fixed coil polarity.
3. Relay may pull in with less than “Must Operate” value.
4. Relay adjustment may be affected if undue pressure is exerted
on relay case.
5. For complete isolation between the relay’s magnetic fields, it is
recommended that a .197" (5.0 mm) space be provided between
adjacent relays.
6. Specifications subject to change without notice.
GENERAL DATA
Life Expectancy
Mechanical
Electrical
Minimum operations
1 x 108
2 x 105 at 1A, 30 VDC resistive
1 x 105 at 0.5A, 125VAC resistive
Operate Time (typical) 3 ms at nominal coil voltage
Release Time (typical) 3 ms at nominal coil voltage
(with no coil suppression)
Dropout
Greater than 10% of nominal coil voltage
Dielectric Strength
(at sea level)
1000 Vrms between contact sets
750 Vrms across contacts
1000 Vrms contact to coil
Meets FCC part 68.302 1500 V lightning
surge
Insulation Resistance 1000 megohms min. at 25°C, 500 VDC,
50% RH
Humidity
5% to 85% RH
Ambient Temperature
Operating
Vibration
Functional
Destructive
At nominal coil voltage
-40°C (-40°F) to 70°C (185°F)
.118” DA 10 to 55 Hz
.197” DA 10 to 55Hz
Shock
Functional
Destructive
50 G
100 G
Enclosure
Plastic sealed
Terminals
copper alloy, DIP, SMT
Weight
1.5 grams
06/01/15