English
Language : 

HX104X01-210 Datasheet, PDF (9/30 Pages) AZ Displays – Preliminary Product Specification
PRODUCT GROUP
REV
ISSUE DATE
TFT-LCD PRODUCT
P3
2009.02.17
4.0 OPTICAL SPECIFICATION
The test of Optical specifications shall be measured in a dark room (ambient luminance 1 lux and
temperature = 25±2℃) with the equipment of Luminance meter system (Goniometer system and
TOPCONE BM-5) and test unit shall be located at an approximate distance 50cm from the LCD
surface at a viewing angle of θ and Φ equal to 0°. We refer to θØ=0 (=θ3 ) as the 3 o’clock
direction (the right”), θØ=90 (= θ12 ) as the 12 o’clock direction (“upward”), θØ=180 (= θ9 ) as the 9
o’clock direction (“left”) and θØ=270(= θ6 ) as the 6 o’clock direction (“bottom”). While scanning
θand/or Ø, the center of the measuring spot on the Display surface shall stay fixed. The backlight
should be operating for 30 minutes prior to measurement. VDD shall be 3.3+/- 0.3V at 25°C.
Optimum viewing angle direction is 6 o’clock.
PARAMETER
SYMBOL CONDITION
Viewing Angle
Range
Θ3
Horizontal
Θ9
Θ12
Vertical
Θ6
Luminance Contrast ratio
CR
CR > 10
Θ = 0°
MIN.
-
-
-
-
400
Luminance of
White
White Luminance
Uniformity
Center
5 Points
13 Points
White Chromaticity
Red
Reproduction of
Color
Green
Blue
Yw
ΔY5
ΔY13
xw
yw
xR
yR
xG
yG
xB
yB
Θ = 0°
Θ = 0°
250
80
65
0.273
0.289
Θ = 0°
- 0.04
Color Reproduction
-
TYP.
89
89
89
89
600
300
85
75
0.313
0.329
T.B.D.
T.B.D.
T.B.D.
T.B.D.
T.B.D.
T.B.D.
40
MAX.
90
90
90
90
-
-
-
-
0.353
0.369
+0.04
-
UNIT
Deg.
REMARK
Deg.
Deg.
Note 1
Deg.
Note 2
cd/m2 Note 3
Note 4
Note 5
%
Response Time
Cross Talk
Tr +Td
Ta= 25° C
Θ = 0°
-
CT
Θ = 0°
-
36
-
ms Note 6
-
2.0
% Note 7
SPEC. NUMBER
TD-0006788
B2005-C001-C(3/3)
SPEC. TITLE
HX104X01-210 Preliminary Product Specification
PAGE
9 / 30