10.0 RELIABILITY TEST
Storage Condition
Operation at high
temperature and
humidity
High temperature
storage
Low temperature
storage
Content
40ºC,90%
RH,240hrs
60ºC,
240hrs
-20ºC,
240hrs
Evaluations and Assessment*
Current
Oozing
Contrast
Consumption
Twice initial
none More than 80% of
value or less
initial value
Other Appearances
No abnormality
Twice initial
value or less
Twice initial
value or less
none
More than 80% of
initial value
More than 80% of
initial value
No abnormality
No abnormality
*Evaluations and assessment to be made two hours after returning to room temperature (25ºC±5ºC).
*The LCDs subjected to the test must not have dew condensation.
AZ DISPLAYS, INC.
09/17/99
7