2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Operating Ambient Temperature
Storage Temperature
Symbol
TOP
TST
Value
Min.
Max.
-30
+70
-40
+80
Unit
Note
ºC (0), (1), (2)
ºC
(0), (1)
Test Item
High Temperature Storage Test
Low Temperature Storage Test
Thermal Shock Storage Test
High Temperature Operation Test
Low Temperature Operation Test
High Temperature & High Humidity
Operation Test
Heat Cycle Operation Test
Test Condition
80ºC, 240 hours
-40ºC, 240 hours
-40ºC, 0.5hour 80 , 0.5hour; 100cycles, 1hour/cycle
70ºC, 240 hours
-30ºC, 240 hours
60ºC, RH 90%, 240hours
-30ºC, 1hour 70ºC, 1hour; 50cycles, 4hour/cycle
150pF, 330 , 1sec/cycle
ESD Test (Operation)
Condition 1 : panel contact, 8KV
Condition 2 : panel non-contact 15KV
Shock (Non-Operating)
Vibration (Non-Operating)
200G, 2ms, half sine wave, 1 time for ± X, ± Y, ± Z.
1.5G, 10 ~ 300 Hz, 10min/cycle, 3 cycles each X, Y, Z
Note (0) All test conditions are as above table.
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note
(1) (2)
(2)
(2)(3)
(2)(3)
Note (2) No display malfunctions.
Note (3) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
Note (4) Temperature of panel display surface area should be 80 ºC Max.
6 / 26