English
Language : 

G133I1-L02 Datasheet, PDF (5/27 Pages) AZ Displays – TFT LCD Approval Specification
Issued Date: Aug. 26, 2008
Model No.: G133I1 - L02
Approval
2. ABSOLUTE MAXIMUM RATINGS
2.1 ABSOLUTE RATINGS OF ENVIRONMENT
Item
Operating Ambient Temperature
Storage Temperature
Symbol
TOP
TST
Value
Min.
Max.
-30
+70
-30
+80
Unit
Note
ºC (0), (1), (2)
ºC
(0), (1)
Test Item
High Temperature Storage Test
Low Temperature Storage Test
Thermal Shock Storage Test
High Temperature Operation Test
Low Temperature Operation Test
High Temperature & High Humidity
Operation Test
Heat Cycle Operation Test
ESD Test (Operation)
Shock (Non-Operating)
Vibration (Non-Operating)
Test Condition
80ºC, 240 hours
-30ºC, 240 hours
-30ºC, 0.5hour 80 , 0.5hour; 100cycles, 1hour/cycle
70ºC, 240 hours
-30ºC, 240 hours
60ºC, 90%RH, 240hours
-20ºC, 1hour 70ºC, 1hour; 50cycles, 4hour/cycle
150pF, 330 , 1sec/cycle
Condition 1 : panel contact, 8KV
Condition 2 : panel non-contact 15KV
200G, 2ms, half sine wave, 1 time for ± X, ± Y, ± Z.
1.5G,10~300Hz,10min/cycle,3 cycles each X,Y,Z
Note
(1) (2)
(2)
(2)(3)
(2)(3)
Note (1) Temperature and relative humidity range is shown in the figure below.
(a) 90 %RH Max. (Ta 40 ºC).
(b) Wet-bulb temperature should be 39 ºC Max. (Ta > 40 ºC).
(c) No condensation.
Note (2) No display malfunctions.
Note (3) At testing Vibration and Shock, the fixture in holding the module has to be hard and rigid enough
so that the module would not be twisted or bent by the fixture.
Note (4) Temperature of panel display surface area should be 80 ºC Max.
Note (5) In the standard conditions, there is no function failure issue occurred. All the cosmetic specification
is judged before the reliability test
5 / 27
The information described in this technical specification is preliminary and it is possible to be changed without prior