English
Language : 

G104X1-L03 Datasheet, PDF (20/27 Pages) AZ Displays – TFT LCD Tentative Specification
Issued Date: May 25, 2009
Model No.: G104X1-L03
Tentative
Note (4) Definition of Luminance of White (LC):
Measure the luminance of gray level 255 at center point and 5 points
LC = L (5), where L (X) is corresponding to the luminance of the point X at the figure in Note (7).
Note (5) Definition of Cross Talk (CT):
CT = | YB – YA | / YA ) 100 (%)
Where:
YA = Luminance of measured location without gray level 0 pattern (cd/m2)
YB = Luminance of measured location with gray level 0 pattern (cd/m2)
(0, 0)
YA, L (D/8,W/2)
YA, D (D/2,7W/8)
Active Area
Gray 128
YA, U (D/2,W/8)
(0, 0)
(D/4,W/4)
YB, L (D/8,W/2)
YA, R (7D/8,W/2)
(D,W)
YB, D (D/2,7W/8)
Active Area
YB, U (D/2,W/8)
GGraryay0 0
Gray 128
YB, R (7D/8,W/2)
(3D/4,3W/4)
(D,W)
Note (6) Measurement Setup:
The LCD assembly should be stabilized at given temperature for 30 minutes to avoid abrupt
temperature change during measuring. In order to stabilize the luminance, the measurement
should be executed after lighting Backlight for 30 minutes in a windless room.
LCD Module
LCD Panel
USB2000
CS-1000T
Field of View = 2º
Center of the Screen
500 mm
Light Shield Room
(Ambient Luminance < 2 lux)
20/27
Version0.0