9. Reliability Test:
No.
Items
1 High Temp. Storage
2 Low Temp. Storage
3 High Temp. Operation
4 Low Temp. Operation
5 High Temp / Humidity Storage
6 High Temp / Humidity Operation
7 Thermal shock
8 Vibration
9 Drop
10 ESD
Document No.:
Specification
85°C, 240hrs
-40°C, 240hrs
70°C, 240hrs
-40°C, 240hrs
85°C, 85%RH, 240hrs
60°C, 90%RH, 240hrs
-40°C ~85°C (-40°C /30min; transit/3min;
85°C /30min; transit /3min)
1cycle: 66min, 100 cycles
Frequency: 5~50HZ, 0.5G
Scan rate: 1 oct/min
Time: 2 hrs/axis
Test axis: X, Y, Z
Height: Follow ISTA spec.
Sequence : 1 angle、3 edges and 6 faces
Cycles: 1
Air discharge model, ±8kV, 10 times
Test and measurement conditions
¾ All measurements shall not be started until the specimens attain to temperature stability.
¾ The degradation of Polarizer is ignored for item 1, 5 & 6.
¾ The test pattern at operating condition is 30%P.C. alternating pictures.
Evaluation Criteria
¾ No damage to glass or encapsulation
¾ No drastic change to display
¾ Defects / Mura follow product specification
¾ Luminance: Within +/-50% of initial value
¾ Current consumption: within +/-50% of initial value
18