English
Language : 

AQM1264PA Datasheet, PDF (16/17 Pages) AZ Displays – SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY
AQM1264PA-NLW-BBW (AZ DISPLAYS) GRAPHIC MODULE VER2.0
Only properly grounded soldering irons should be used.
If an electric screwdriver is used, it should be well grounded and shielded from commutator sparks.
The normal static prevention measures should be observed for work clothes and working benches; for the latter
conductive (rubber) mat is recommended.
c) Floor
Floor is the important part to drain static electricity, which is generated by operators or equipment.
There is a possibility that charged static electricity is not properly drained in case of insulating floor. Set the
electrostatic earth (electrostatic earth: 1x108 ohm).
d) Humidity
Proper humidity helps in reducing the chance of generating electrostatic charges. Humidity should be kept over
50%RH.
e) Transportation/storage
The storage materials also need to be anti-static treated because there is a possibility that the human body or storage
materials such as containers may be statically charged by friction or peeling.
The modules should be kept in antistatic bags or other containers resistant to static for storage.
f) Soldering
Solder only to the I/O terminals.Use only soldering irons with proper grounding and no leakage.
Soldering temperature : 280°C ± 10°C
Soldering time: 3 to 4 sec.
Use eutectic solder with resin flux fill.
If flux is used, the LCD surface should be covered to avoid flux spatters. Flux residue should be removed
afterwards.
g) Others
The laminator (protective film) is attached on the surface of LCD panel to prevent it from scratches or stains. It should
be peeled off slowly using static eliminator.
Static eliminator should also be installed to the workbench to prevent LCD module from static charge.
10. Operation
a) Driving voltage should be kept within specified range; excess voltage shortens display life.
b) Response time increases with decrease in temperature.
c) Display may turn black or dark blue at temperatures above its operational range; this is (however not
pressing on the viewing area) may cause the segments to appear “fractured”.
d) Mechanical disturbance during operation (such as pressing on the viewing area) may cause the
segments to appear “fractured”.
11. If any fluid leaks out of a damaged glass cell, wash off any human part that comes into contact with soap and
water. The toxicity is extremely low but caution should be exercised at all the time.
12. Disassembling the LCD module can cause permanent damage and it should be strictly avoided.
13. LCD retains the display pattern when it is applied for long time (Image retention). To prevent image retention,
do not apply the fixed pattern for a long time. Image retention is not a deterioration of LCD. It will be removed
after display pattern is changed.
14. Do not use any materials, which emit gas from epoxy resin (hardener for amine) and silicone adhesive agent