11. Interface Timing
11.1) Timing Parameters
AC Electrical Characteristics (VCC=VDD1= 3.3V, VDD2=9.5V, GND=VSS1=VSS2=0V, Ta=25ଇ)
Parameter
Symbol Min. Typ. Max. Unit
CLK Frequency
Fclk
-
32
40
MHz
CLK Pulse Width
Tcw
25
-
-
ns
Data Set-up Time
Tsu
4
-
-
ns
Data Hold Time
Thd
2
-
-
ns
Propagation Delay of DIO2/1
Tphl
6
10
15
ns
Time That The Last Data to LD
Tld
1
-
-
Tcw
Pulse width of LD
Twld
2
-
-
Tcw
Time That LD to DIO1/2
Tlds
5
-
-
Tcw
POL Set-up Time
Tpsu
6
-
-
ns
POL Hold Time
Tphd
6
-
-
ns
OE Pulse Width
TOEV
1
-
-
µs
CKV Pulse Width
TCKV
500
-
-
ns
STV Set-up Time
TSUV
400
-
-
ns
STV Hold Time
THDV
400
-
-
ns
Horizontal Display Period
THDP
-
800
-
Tcw
Horizontal Period Timing Range
THP
-
1056
-
Tcw
Horizontal Lines Per Field
TV
484 508 620
THP
Vertical Display Timing Range
TDV
-
480
-
THP