English
Language : 

ATM0280B17-T_14 Datasheet, PDF (12/16 Pages) AZ Displays – LIQUID CRYSTAL DISPLAY
ATM0280B17(AZ DISPLAYS)TFT MODULE V1.0
5. RELIABILITY TEST
NO..
Test Item
Description
Test Condition
High temperature Endurance test applying the
1
storage
high storage temperature for a 80℃,240 H
long time
Low temperature Endurance test applying the
2
storage
low storage temperature for a -30℃,240H
long time
High temperature Endurance test applying the
3
operation
electric stress under high
60℃,96H
temperature for a long time
Low temperature Endurance test applying the
4
operation
electric stress under low
-10℃,96H
temperature for a long time
High temperature Endurance test applying the
5
/humidity storage high temperature and high
humidity storage for a long
50℃,90% R.H
240H
time
High temperature Endurance test applying
6
/humidity operation electric stress under high
temperature and high humidity
40℃ 90% R.H 96H
for a long time
Remark
Note 1
Note 4
Note 1
Note 4
Note 2
Note 4
Note 1
Note 4
Note 4
Note 4
Endurance test applying the
7
Temperature Cycle
low and high temperature cycle
-20℃ → 25℃ → 70℃ →25℃
-20℃/70℃ 10 cycles
30min 5min 30min 5min one
cycle
Endurance test applying the 10Hz~50Hz
8
Vibration test vibration during transportation Swing:0.75mm
and using
time:30min
9
Fall test
Endurance test dropping the
LCM from a high place
600mm height
Contact discharge:
10
Static electricity Endurance test applying static ±2KV~4KV Air
test
electric stress to terminal
discharge:
±2KV~10KV
Note 1: Ta is the ambient temperature of samples.
Note 2: Ts is the temperature of panel’s surface.
Note 3: In the standard condition, there shall be no practical problem that may affect the
display function. After the reliability test, the product only guarantees operation,
but don’t guarantee all of the cosmetic specification.
Note 4: Before cosmetic and function test, the product must have enough recovery time, at least 2 hours
at room temperature.
AZ DISPLAYS
11