1. Electrical specification
Parameter
Nominal frequency
Frequency stability
Initial tolerance before screening test
Initial tolerance after screening test
vs. operating temperature range
vs. supply voltage variation
vs. load change
Long term (aging) per day
Long term (aging) 1st year
Long term (aging) following 9 years
RF output
Signal waveform
Load RL
Output level
Harmonics
Spurious
Min.
+12
Warm-up time @ +25°C
@ -30°C
Phase noise in quiet state
Phase noise floor
Short term stability (Allan deviation)
Acceleration sensitivity
Supply voltage VS
11.4
Current consumption (steady state)
Current consumption (warm-up)
Operating temperature range
-30
Table 1 – Electrical Performance and Characteristics
Typ. Max.
100.000
±10
±200
±50
±500
±50
±5
±5
±2
±50
±200
Sine wave
50
+13
+14
-35
-80
-80
20
20
-73
-70
-105 -100
-135 -130
-156 -153
-165 -160
-165
5·10-12 1·10-10
0.5
1.0
12.0 12.6
200
350
350
450
450
800
+70
Unit
MHz
ppb
ppb
ppb
ppb
ppb
ppb
ppb
ppb
Ω
dBm
dBc
dBc
dBc
min
min
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ppb/g
V
mA
mA
mA
°C
Condition
@ +25°C
@ +25°C
VS ±5%
RL ±10%
after 30 days operation
after 30 days operation
after 30 days operation
±10%
f0 ±1 MHz
DC to 1.6 GHz
∆f/f0 < ±10 ppb
∆f/f0 < ±20 ppb
@ 1 Hz
@ 10 Hz
@ 100 Hz
@ 1 kHz
@ 9.999 kHz
@ ≥ 100 kHz
@ τ = 1 sec
per axis
@ +25°C
@ -30°C
Notes:
1.
2.
Terminology and test conditions are according to IEC standard IEC60679-1, MIL-PRF-55310 and ESCC21300,
unless otherwise stated
Classification (MIL-PRF-55310): Type 4 (OCXO), Class 1 (Discrete Technology), Product Level “S”
Absolute Maximum Ratings
Parameter
Supply Voltage VS
Load RL
Operable temperature range
Storage temperature range
Table 2 – Maximum Ratings
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Min.
0
0
-35
-40
Max. Unit
12.6 V
∞Ω
+75 °C
+80 °C
Condition Remark
VS to GND
-
-
-
Overshoot survivability in
acc. with generic specification
Must not cause any damage
Operation of unit without any
harm or damage
AXIOM6060 Rev.5
Drawing D1
Page 3(14)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com