English
Language : 

QF2600 Datasheet, PDF (2/2 Pages) Advanced XTAL Products – Front End ( Antenna) Crystal Filter
Enclosure drawing
Pin connections
Terminal Symbol Function
1*
IN Input
2*
OUT Output
screw GND Ground, Case
* marking on request only
Environmental conditions
Test
IEC 60068 IEC 61178-1
Part ...
clause ...
Visual inspection,
4.5
dimensions
4.6
Sealing tests
2-17
4.8.2
Solderability
Resistance to
soldering heat
Shock
2-20
2-27
4.8.3
4.8.8
Bump
2-29
4.8.6
Free fall
2-32
4.8.9
Vibration,
sinusoidal
2-6
4.8.7
Rapid change of
temperature
2-14
4.8.5
Dry heat
2-2
4.8.11
Damp heat, cyclic
Cold
2-30
2-1
4.8.12
4.8.13
Climatic sequence 1-7
4.8.14
Damp heat, steady 2-3
state
Endurance tests
- ageing
- extended aging
4.8.15
4.9.1
4.9.2
Test conditions
Enclosure styles as in IEC
60368-3, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6
ms half-sine pulse
Test Eb, 4000 bumps per
Axes, 40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz
- 2 kHz, 10g
Test Na, 10 cycles at
extremes of operating
temperature range
Test Ba, 16 h at upper
temperature indicated by
climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower
temperature indicated by
climatic category
Sequence of 4.8.11, 4.8.12
(1st cycle), 4.8.13, 4.8.12 (5
cycles)
Test Ca, 56 days
30 days @ 85°C
1000h, 2000h, 8000h @85°C
Products
Buchfinkenweg 8
DE-74931 Lobbach
Germany
page 2(2)
wwwAXTAL.com
phone: +49 (6226) 9719689
fax: +49 (6226) 970133
E-mail: info@axtal.com