English
Language : 

AXIOM95 Datasheet, PDF (2/2 Pages) Advanced XTAL Products – VHF OCXO with SMA connector
Enclosure drawing
Pin connections
Pin# Symbol Function
1
VC Control Voltage
(EFC)
2
GND Ground
3
VS Supply Voltage
SMA RF OUT RF Output
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Solderability
2-20
Resistance to
2-58
soldering heat
Shock*
2-27
IEC 60679-1
clause ...
4.3
4.6.3
4.6.8
Bump*
Free fall*
2-29
4.6.6
2-32
4.6.9
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
2-14
temperature
Dry heat
2-2
4.6.5
4.6.14
Damp heat, cyclic* 2-30
4.6.15
Cold
2-1
4.6.16
Climatic sequence* 1-7
4.6.17
Damp heat, steady 2-3
state*
Endurance tests
- ageing
- extended aging
4.6.18
4.7.1
4.7.2
Test conditions
Enclosure styles as in IEC 60679-3 or 61837,
if applicable
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms half-sine
pulse
Test Eb, 4000 bumps per Axes, 40g, 6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g
Test Na, 10 cycles at extremes of operating
temperature range
Test Ba, 16 h at upper temperature indicated
by climatic category
Test Db variant 1 severity b), 55°C/95% r.H.,
6 cycles
Test Aa, 2 h at lower temperature indicated by
climatic category
Sequence of 4.6.14, 4.6.15 (1st cycle), 4.6.16,
4.6.15 (5 cycles)
Test Ca, 56 days
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXIOM95
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com