English
Language : 

AXHV4001H Datasheet, PDF (2/2 Pages) Advanced XTAL Products – VCO - Voltage Controlled Oscillator
Enclosure drawing
Package drawing on request
Pin connections
Pin # Symbol Function
P1
VC Control Voltage (EFC)
P2 RF OUT RF Output
P3
VS Supply Voltage
P4 N.C. Not Connected
All GND Ground
others
Environmental conditions
Test
IEC 60068
Part ...
Visual inspection,
dimensions
Sealing tests
2-17
(if applicable)
Solderability
2-20
Resistance to
2-58
soldering heat
Shock*
2-27
IEC 60679-1
clause ...
4.3
4.6.2
4.6.3
4.6.8
Bump*
2-29
4.6.6
Free fall*
2-32
4.6.9
Vibration, sinusoidal* 2-6
4.6.7
Rapid change of
2-14
temperature
Dry heat
2-2
Damp heat, cyclic* 2-30
Cold
2-1
Climatic sequence* 1-7
Damp heat, steady 2-3
state*
Endurance tests
- ageing
- extended aging
4.6.5
4.6.14
4.6.15
4.6.16
4.6.17
4.6.18
4.7.1
4.7.2
Test conditions
Enclosure styles as in IEC 60679-3
or 61837, if applicable
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta (235 ± 5)°C Method 1
Test Tb Method 1A, 5s
Test Ea, 3 x per axes 100g, 6 ms
half-sine pulse
Test Eb, 4000 bumps per Axes, 40g,
6 ms
Test Ed procedure 1,
2 drops from 1m height
Test Fc, 30 min per axes,
10 Hz - 55 Hz 0,75mm; 55 Hz - 2
kHz, 10g
Test Na, 10 cycles at extremes of
operating temperature range
Test Ba, 16 h at upper temperature
indicated by climatic category
Test Db variant 1 severity b),
55°C/95% r.H., 6 cycles
Test Aa, 2 h at lower temperature
indicated by climatic category
Sequence of 4.6.14, 4.6.15 (1st
cycle), 4.6.16, 4.6.15 (5 cycles)
Test Ca, 56 days
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
GmbH & Co. KG
Wasemweg 5
D-74821 Mosbach
Germany
AXHV4001H
page 2(2)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: info@axtal.com