TLCL226M006XTA Datasheet, PDF (4/4 Pages) AVX Corporation – Tantalum Solid Electrolytic Chip Capacitors Consumer Series
TLC Series
Tantalum Solid Electrolytic Chip Capacitors
Consumer Series
RATINGS & PART NUMBER REFERENCE
AVX
Part No.
TLCK474M016#TA
TLCK105M016#TA
TLCL335M016#TA
TLCV106M016#TA
TLCH225M020#TA
TLCR106M020#TA
TLCL105M025#TA
TLCR225M025#TA
TLCR105M035#TA
Case Capacitance
Size
(μF)
Rated
Voltage
(V)
Rated Category Category
Temperature Voltage Temperature
(ºC)
(V)
(ºC)
DCL
(μA)
Max.
ESR
Max. (Ω)
@ 100kHz
MSL
16 Volt @ 40°C
K
0.47
16
40
3.2
125
0.5
15
3
K
1
16
40
3.2
125
0.8
15
3
L
3.3
16
40
3.2
125
0.5
7.5
3
V
10
16
40
3.2
125
1.6
2
3
20 Volt @ 40°C
H
2.2
20
40
4
125
0.5
7.5
3
R
10
20
40
4
125
0.6
5
3
25 Volt @ 40°C
L
1.0
25
40
5
125
0.5
7.5
3
R
2.2
25
40
5
125
0.6
5
3
35 Volt @ 40°C
R
1.0
35
40
7
125
0.5
5
3
100kHz RMS Current (mA)
25ºC
85ºC 125ºC
32
28
13
32
28
13
58
52
23
132 119 53
89
80
36
95
85
38
58
85
23
95
85
38
95
85
38
Moisture Sensitivity Level (MSL) is defined according to J-STD-020.
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts.
DCL is measured at rated voltage after 5 minutes.
DCL allowed to move up to 2.00 times the limit post mounting.
For typical weight and composition see page 214.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
QUALIFICATION TABLE
TEST
Endurance
TLC series (Temperature range -55ºC to +125ºC)
Condition
Characteristics
Determine after application of rated voltage for 2000
+48/-0 hours at 40±2ºC and then leaving 1-2 hours at
room temperature. Also determine of 85ºC tempera-
ture, category voltage for 2000 +48/-0 hours and
then leaving 1-2 hours at room temperature. Power
supply impedance to be ≤0.1Ω/V.
Visual examination
DCL
ΔC/C
no visible damage
1.25 x initial limit
within ±30% of initial value
DF
1.5 x initial limit
Humidity
Temperature
Stability
Surge
Voltage
Determine after storage without applied voltage
at 40±2ºC and 90-95% relative humidity for 56
days and then recovery 1-2 hours at room
temperature.
Visual examination no visible damage
DCL
2 x initial limit
ΔC/C
±30% of initial value
Step
1
2
3
4
5
6
7
8
Temperature°C
+20±2
-55+0/-3
+20±2
+40+2/-0
+60+2/-0
+85+3/-0
+125+3/-0
+20±2
Duration (min) Voltage Applied
15
N/A
15
N/A
15
N/A
15
VR
15
0.66 x VR
15
0.50 x VR
15
0.20 x VR
15
N/A
DF
DCL
ΔC/C
DF
1.25 x initial limit
+20ºC -55ºC +20ºC +40ºC +60ºC +85ºC +125ºC +20ºC
IL* n/a IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* IL*
n/a +0/-25% ±5% +10/-0% +10/-0% +20/-0% +25/-0% +20/-10%
IL* n/a 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL* 1.25 x IL*
Test temperature: 40ºC+3/0ºC
Test voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
Visual examination no visible damage
DCL
2 x initial limit
ΔC/C
within ±30% of initial value
DF
1.25 x initial limit
*Initial Limit
JANUARY 2015 ■ 59