PRODUCT CATEGORY 105°C
TEST
Endurance
Storage Life
Humidity
Temperature
Stability
105°C series (Temperature range -55ºC to +105ºC)
Condition
Characteristics
Determine after application of rated voltage for 2000
+48/-0 hours at 85±2ºC and then leaving 1-2 hours at
room temperature. Also determine after application of
105ºC temperature, category voltage for 2000 +48/-0
hours and then leaving 1-2 hours at room tempera-
ture. Power supply impedance to be ≤ 0.1Ω/V.
Visual examination
DCL
ΔC/C
DF
ESR
no visible damage
1.25 x initial limit
within +10/-20% of initial value for Ur ≤ 16V
within +20/-30% of initial value for Ur ≥ 20V
1.5 x initial limit
2 x initial limit
Visual examination
no visible damage
105ºC, 0V, 2000h
DCL
ΔC/C
1.25 x initial limit
within +10/-20% of initial value for Ur ≤ 16V
within +20/-30% of initial value for Ur ≥ 20V
DF
1.5 x initial limit
ESR
2 x initial limit
Visual examination
no visible damage
Determine after storage without applied voltage
at 65±2ºC and 95±2% relative humidity for 500
hours and then recovery 1-2 hours at room
temperature.
DCL
ΔC/C
DF
3 x initial limit
within +30/-20% of initial value
1.5 x initial limit
ESR
2 x initial limit
Step
1
2
3
4
5
6
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+105+3/-0
+20±2
Duration(min)
15
15
15
15
15
15
DCL
ΔC/C
DF
+20ºC -55ºC
IL*
n/a
n/a +0/-20%
IL* 1.5 x IL*
+20ºC +85ºC +105ºC +20ºC
IL* 10 x IL* 12.5 x IL* IL*
±5% +20/-0% +30/-0% ±5%
IL* 1.5 x IL* 2 x IL* IL*
Surge
Voltage
*Initial Limit
Test temperature: 105ºC+3/0ºC
Test voltage: Category voltage at 105ºC
Surge voltage: 1.3 x category voltage at 105ºC
Series protection resistance 1000±100Ω
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
Visual examination
DCL
ΔC/C
DF
no visible damage
initial limit
within +10/-20% of initial value for Ur ≤ 16V
within +20/-30% of initial value for Ur ≥ 20V
1.25 x initial limit
PRODUCT CATEGORY 85°C
TEST
Endurance
Storage Life
Humidity
Temperature
Stability
85°C series (Temperature range -55ºC to +85ºC)
Condition
Characteristics
Visual examination
no visible damage
Determine after application of rated voltage for 2000
DCL
1.25 x initial limit
+48/-0 hours at 85±2ºC and then leaving 1-2 hours
ΔC/C
within +10/-20% of initial value for Ur ≤ 16V
at room temperature. Power supply impedance to be
≤0.1Ω/V.
DF
within +20/-30% of initial value for Ur ≥ 20V
1.5 x initial limit
ESR
2 x initial limit
Visual examination
no visible damage
DCL
1.25 x initial limit
85ºC, 0V, 2000h
ΔC/C
within +10/-20% of initial value for Ur ≤ 16V
within +20/-30% of initial value for Ur ≥ 20V
DF
1.5 x initial limit
ESR
2 x initial limit
Determine after storage without applied
voltage at 65±2ºC and 95±2% relative
humidity for 500 hours and then recovery
1-2 hours at room temperature.
Visual examination
DCL
ΔC/C
DF
ESR
no visible damage
5 x initial limit
within +40/-20% of initial value
1.5 x initial limit
2 x initial limit
Step
1
2
3
4
5
Temperature°C
+20±2
-55+0/-3
+20±2
+85+3/-0
+20±2
Duration(min)
15
15
15
15
15
DCL
ΔC/C
DF
+20ºC
IL*
n/a
IL*
-55ºC
n/a
+0/-20%
1.5 x IL*
+20ºC
IL*
±5%
IL*
+85ºC
10 x IL*
+20/-0%
1.5 x IL*
+20ºC
IL*
±5%
IL*
Surge
Voltage
Test temperature: 85+3/0ºC
Test voltage: Rated voltage
Surge voltage: 1.3 x rated voltage
Series protection resistance 1000±100Ω.
Discharge resistance: 1000Ω
Number of cycles: 1000x
Cycle duration: 6 min; 30 sec charge,
5 min 30 sec discharge
Visual examination
DCL
ΔC/C
DF
no visible damage
initial limit
within +10/-20% of initial value for Ur ≤ 16V
within +20/-30% of initial value for Ur ≥ 20V
1.25 x initial limit
*Initial Limit
For use outside of recommended conditions and special request, please contact manufacturer.
122 ■ JULY 2015