TCME108M004R0010 Datasheet, PDF (2/2 Pages) AVX Corporation – Tantalum Solid Electrolytic Chip Capacitors Conductive Polymer Multianode
TCM Series
Tantalum Solid Electrolytic Chip Capacitors
Conductive Polymer Multianode
CAPACITANCE AND RATED VOLTAGE, VR (VOLTAGE CODE) RANGE
(LETTER DENOTES CASE SIZE)
Capacitance
μF Code
22 226
33 336
47 476
68 686
100 107
150 157
220 227
330 337
470 477
680 687
1000 108
1500 158
4V (G)
E(10,12)
Rated Voltage DC (VR) to 85°C
6.3V (J)
10V (A)
E*
E(10)
E*
E*
35V (V)
E(25)
Available Ratings, (ESR ratings in mOhms in brackets)
Engineering samples - please contact manufacturer
*Codes under development – subject to change
Note: Voltage ratings are minimum values. AVX reserves the right to supply
higher ratings in the same case size, to the same reliability standards.
RATINGS & PART NUMBER REFERENCE
AVX
Part No.
TCME108M004#0010
TCME108M004#0012
TCME337M006#0010
TCME447M006#0010
TCME337M010#0010
TCME226M035#0025
Case Capacitance
Size
(μF)
E
1000
E
1000
E
330
E
470
E
330
E
22
Rated
Voltage
(V)
4
4
6.3
6.3
10
35
DCL DF ESR
100kHz RMS Current (mA)
(μA) % Max. (mΩ) MSL
Max. Max. @100kHz
25ºC
85ºC
105ºC
4 Volt @ 85°C (3.2 Volt @ 105°C)
400 8
10
3 4062
3656
2640
400 8
12
3 3708
3337
2410
6.3 Volt @ 85°C (5 Volt @ 105°C)
198 8
10
3 4062
3656
2640
282 8
10
3 4062
3656
2640
10 Volt @ 85°C (8 Volt @ 105°C)
330 8
10
3 4062
3656
2640
35 Volt @ 85°C (28 Volt @ 105°C)
77 8
25
3 2569
2312
1670
100kHz RMS Voltage (mV)
25ºC
85ºC
105ºC
41
37
26
44
40
12
41
37
26
41
37
26
41
37
26
64
58
42
Moisture Sensitivity Level (MSL) is defined according to J-STD-020.
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2 volts.
DCL is measured at rated voltage after 5 minutes.
ESR allowed to move up to 1.25 times catalog limit post mounting.
For typical weight and composition see page 123.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
100%
90% 100%
80%
70% 80%
60%
50%
40%
30%
20%
10%
0%
-55°C
Voltage vs Temperature Rating
100%
80%
0°C
40°C
60°C
85°C
80%
Rated range
Recommended derating
105°C
54