MLCC with FLEXITERM®
Specifications and Test Methods
PERFORMANCE TESTING
AEC-Q200 Qualification:
• Created by the Automotive Electronics
Council
• Specification defining stress
test qualification for
passive components
Testing:
Key tests used to compare
soft termination to
AEC-Q200 qualification:
• Bend Test
• Temperature Cycle Test
BOARD BEND TEST RESULTS
AEC-Q200 Vrs AVX FLEXITERM® Bend Test
12
10
8
6
4
2
0
NPO
0603
X7R X7R soft term
12
10
8
6
4
2
0
NPO
12
10
8
6
4
2
0
NPO
1206
X7R X7R soft term
12
10
8
6
4
2
0
NPO
BOARD BEND TEST PROCEDURE
According to AEC-Q200
Test Procedure as per AEC-Q200:
Sample size:
20 components
Span: 90mm
Minimum deflection spec: 2 mm
• Components soldered onto FR4 PCB (Figure 1)
• Board connected electrically to the test equipment
(Figure 2)
BEND TESTPLATE
DIGITAL
CALIPER
LOADING
KNIFE
MOUNTING
ASSEMBLY
CONNECTOR
CONTROL PANEL
Fig 1 - PCB layout with electrical connections
CONTROL
PANEL
Fig 2 - Board Bend test
equipment
0805
X7R X7R soft term
1210
AVX ENHANCED SOFT
TERMINATION BEND TEST
PROCEDURE
Bend Test
The capacitor is soldered to the printed circuit
board as shown and is bent up to 10mm at
1mm per second:
X7R X7R soft term
Max. = 10mm
TABLE SUMMARY
Typical bend test results are shown below:
Style Conventional Termination
FLEXITERM®
0603 >2mm
>5mm
0805 >2mm
>5mm
1206 >2mm
>5mm
TEMPERATURE CYCLE TEST PROCEDURE
Test Procedure as per AEC-Q200:
The test is conducted to determine the resistance of the
component when it is exposed to extremes of alternating
high and low temperatures.
• Sample lot size quantity 77 pieces
• TC chamber cycle from -55ºC to +125ºC for 1000 cycles
• Interim electrical measurements at 250, 500, 1000 cycles
• Measure parameter capacitance dissipation factor,
insulation resistance
Test Temperature Profile (1 cycle)
+1250 C
+250 C
-550 C
1 hour 12mins
90mm
• The board is placed on 2 supports 90mm
apart (capacitor side down)
• The row of capacitors is aligned with the
load stressing knife
Max. = 10mm
• The load is applied and the deflection where
the part starts to crack is recorded (Note:
Equipment detects the start of the crack
using a highly sensitive current detection
circuit)
• The maximum deflection capability is 10mm
47