HCPL-0600-000E Datasheet, PDF (9/21 Pages) AVAGO TECHNOLOGIES LIMITED – High CMR, High Speed TTL Compatible Optocouplers | |||
|
◁ |
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-26xx; 46xx; 6N13x Option 060 Only)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
â for rated mains voltage ⤠300 Vrms I-IV
â for rated mains voltage ⤠450 Vrms I-IV
Climatic Classification
40/85/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM
630
V peak
âVIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
â Partial Discharge < 5 pC
VPR
1181
V peak
Input to Output Test Voltage, Method a*
âVIORM x 1.6 = VPR, Type and sample test, tm = 10 sec,
â Partial Discharge < 5 pC
VPR
1008
V peak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
VIOTM
Safety Limiting Values (Maximum values allowed in the event of a failure) â
6000
V peak
ââCase Temperature
ââInput Current
ââOutput Power
Insulation Resistance at TS, VIO = 500 V
TS
IS,INPUT
PS,OUTPUT
RS
175
230
600
â¥109
°C
mA
mW
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCNW137/2601/2611 Only)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
â for rated mains voltage ⤠600 Vrms I-IV
â for rated mains voltage ⤠1000 Vrms I-III
Climatic Classification
40/85/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM
1414
V peak
âVIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
â Partial Discharge < 5 pC
VPR
2651
V peak
Input to Output Test Voltage, Method a*
âVIORM x 1.6 = VPR, Type and sample test, tm = 10 sec,
â Partial Discharge < 5 pC
VPR
2262
V peak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
VIOTM
8000
V peak
Safety Limiting Values (Maximum values allowed in the event of a failure)
ââCase Temperature
ââInput Current
ââOutput Power
TS
150
°C
IS,INPUT
400
mA
PS,OUTPUT
700
mW
Insulation Resistance at TS, VIO = 500 V
RS
â¥109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.
9
|
▷ |