English
Language : 

HCMS-29XX Datasheet, PDF (9/16 Pages) Agilent(Hewlett-Packard) – High Performance CMOS 5 x 7 Alphanumeric Displays
HCMS-29xx Write Cycle Diagram
RS
CE
CLK
D IN
D OUT (SERIAL)
D OUT
(SIMULTANEOUS)
TRSS TRSH
1
2
TCLKCE
3
TCES
4
TCLKH
11
TCEDO
10
TDS
TDH
6
7
TDOUT
8
TDOUTP
9
TCLKL
12
TCEH
5
[1]
NEW DATA LATCHED HERE
LED OUTPUTS,
CONTROL
REGISTERS
PREVIOUS DATA
NOTE:
1. DATA IS COPIED TO THE CONTROL REGISTER OR THE DOT LATCH AND LED OUTPUTS WHEN CE IS HIGH AND CLK IS LOW.
NEW DATA
tions, but only 7 of the 8 rows
have LEDs (see Figures 1 & 2).
The bottom row (row 0) is not
used. Thus, latch location 0 is
never displayed. Column 0
controls the left-most column.
Data from Dot Latch locations
0-7 determine whether or not
pixels in Column 0 are
turned-on or turned-off.
Therefore, the lower left pixel is
turned-on when a logic high is
stored in Dot Latch location 1.
Characters are loaded in
serially, with the left-most
character being loaded first and
the right-most character being
loaded last. By loading one
character at a time and latching
the data before loading the next
character, the figures will
appear to scroll from right to
left.
Control Register
The Control Register allows
software modification of the IC’s
operation and consists of two
independent 7-bit control words.
Bit D7 in the shift register
selects one of the two 7-bit
control words. Control Word 0
performs pulse width modula-
tion brightness control, peak
pixel current brightness control,
and sleep mode. Control Word 1
sets serial/simultaneous data
out mode, and external oscilla-
tor prescaler. Each function is
independent of the others.
Control Register Data Loading
Data is loaded into the Control
Register, MSB first, according to
the procedure shown in Table 1
and the Write Cycle Timing
Diagram. First, RS is brought to
logic high and then CE is
brought to logic low. Next, each
successive rising CLK edge will
shift in the data on the DIN pin.
Finally, when 8 bits have been
loaded, the CE line is brought to
logic high. When CLK goes to
logic low, new data is copied
into the selected control word.
Loading data into the Control
Register takes place while the
previous control word
configures the display.
Control Word 0
Loading the Control Register
with D7 = Logic low selects
Control Word 0 (see Table 2).
Bits D0-D3 adjust the display
brightness by pulse width
modulating the LED on-time,
while Bits D4-D5 adjust the
display brightness by changing
the peak pixel current. Bit D6
selects normal operation or
sleep mode.
9