Insulation and Safety Related Specifications
Parameter
Symbol
8-pin DIP
Widebody
(300 Mil) SO-8 (400 Mil)
Value
Value
Value
Unit
Minimum External
L(101)
7.1
4.9
9.6
mm
Air Gap
(External Clearance)
Minimum External
L(102)
7.4
4.8
10.0
mm
Tracking
(External Creepage)
Minimum Internal
0.08
0.08
1.0
mm
Plastic Gap
(Internal Clearance)
Minimum Internal
NA
NA
4.0
mm
Tracking
(Internal Creepage)
Tracking Resistance
CTI
(Comparative Tracking Index)
200
200
200
V
Isolation Group
IIIa
IIIa
IIIa
Conditions
Measured from input terminals
to output terminals, shortest
distance through air.
Measured from input terminals
to output terminals, shortest
distance path along body.
Through insulation distance,
conductor to conductor, usually
the direct distance between the
photoemitter and photodetector
inside the optocoupler cavity.
Measured from input terminals
to output terminals, along
internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group
(DIN VDE 0110, 1/89, Table 1)
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-06xx Option 060 Only)
Description
Symbol
Characteristic
Unit
Installation classification per DIN VDE 0110, Table 1
  for rated mains voltage ≤ 150 Vrms I-IV
  for rated mains voltage ≤ 300 Vrms I-IV
  for rated mains voltage ≤ 600 Vrms I-III
Climatic Classification
40/85/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method b*
 VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
  Partial Discharge < 5 pC
VIORM
VPR
567
1063
V peak
V peak
Input-to-Output Test Voltage, Method a*
 VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
  Partial Discharge < 5 pC
VPR
907
V peak
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
VIOTM
6000
V peak
Safety Limiting Values (Maximum values allowed in the event of a failure)
  Case Temperature
  Input Current**
  Output Power**
TS
150
°C
IS,INPUT
150
mA
PS,OUTPUT
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.