IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (OPTION 060 ONLY)
Characteristic
Description
Symbol HCPL-4502/4503
Installation classification per DIN VDE 0110/39, Table 1
â for rated mains voltage ⤠300 Vrms I-IV
â for rated mains voltage ⤠600 Vrms
I-IV
Climatic Classification
55/100/21
HCPL-0452/0453
I-IV
I-I I I
55/100/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
âVIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
â Partial Discharge < 5 pC
630
1181
560
1050
Input to Output Test Voltage, Method a*
âVIORM x 1.6 = VPR, Type and sample test,
âtm = 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
â (Maximum values allowed in the event of a failure,
â also see Figure 9, Thermal Derating curve.)
ââCase Temperature
ââInput Current
ââOutput Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
1008
8000
TS
IS,INPUT
PS,OUTPUT
RS
175
230
600
â¥109
896
6000
175
150
600
â¥109
Units
V peak
V peak
V peak
V peak
°C
mA
mW
Ω
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics (HCNW4502/3 ONLY)
ââââââââââââDescription
Symbol
Installation classification per DIN VDE 0110/39, Table 1
â for rated mains voltage â¤600 V rms
â for rated mains voltage â¤1000 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
VIORM
Input to Output Test Voltage, Method b*
âVIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
VPR
â Partial Discharge < 5 pC
Input to Output Test Voltage, Method a*
âVIORM x 1.6 = VPR, Type and sample test,
âtm = 10 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage*
(Transient Overvoltage, tini = 60 sec)
Safety Limiting Values
â (Maximum values allowed in the event of a failure,
â also see Figure 9, Thermal Derating curve.)
ââCase Temperature
ââInput Current
ââOutput Power
Insulation Resistance at TS, VIO = 500 V
VPR
VIOTM
TS
IS,INPUT
PS,OUTPUT
RS
Characteristic
Units
I-IV
I-III
55/85/21
2
1414
V peak
2652
V peak
2262
V peak
8000
V peak
150
°C
400
mA
700
mW
⥠109
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
8
|
▷ |