HCPL-3101-000E Datasheet, PDF (7/14 Pages) AVAGO TECHNOLOGIES LIMITED – Power MOSFET/IGBT Gate Drive Optocouplers
Switching Specifications (TA = 25°C)
Parameter
Sym.
Device Min. Typ.
Propagation
Delay Time to
High Output
Level
tPLH
HCPL-3100 -
1
HCPL-3101 - 0.3
Propagation
Delay Time to
Low Output
Level
tPHL
HCPL-3100 -
1
HCPL-3101 - 0.3
Rise Time
tr
HCPL-3100 - 0.2
HCPL-3101
Fall Time
tf
HCPL-3100 - 0.2
HCPL-3101
Output High
Level Common
Mode Transient
Immunity
|CMH| HCPL-3100 15
HCPL-3101
Output Low
|CML|
15
Level Common
Mode Transient
Immunity
Max. Units
2
µs
0.5 µs
2
µs
0.5 µs
Test Conditions
IF = 10 mA
IF = 5 mA
IF = 10 mA
VCC = 24 V,
VO1 = 24 V,
RG = 47 Ω,
CG = 3000 pF
IF = 5 mA
0.5 µs IF = 10 mA
IF = 5 mA
0.5 µs IF = 10 mA
IF = 5 mA
- kV/µs IF = 10 mA
IF = 5mA
- kV/µs IF = 0 mA
VCM = 1500 V
(peak),
VCC = 24 V
VO1 = 24 V
∆V02H = ∆V02L
= 2.0 V
Fig. Note
9, 2, 6
25,
26,
27
10 2
Packaging Characteristics
Parameter
Input-Output Momentary
Withstand Voltage*
Resistance (Input-Output)
Capacitance (Input-Output)
Sym.
VISO
Min. Typ.
5000
RI-O
5x1010 1011
CI-O
–
1.2
Max.
Units
V rms
–
Ω
–
pF
Test Conditions
RH = 40% to 60%
t = 1 min, TA = 25°C
VI-O = 500 V, TA = 25°C
RH = 40% to 60%
f = 1 MHz
Fig. Note
4, 5
4
4
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output continuous voltage
rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table (if applicable), your equipment level
safety specification, or Avago Application Note 1074, “Optocoupler Input-Output Endurance Voltage.”
Notes:
1. Derate absolute maximum ratings with ambient temperatures as shown in Figures 11 and 12.
2. A bypass capacitor of 0.01 µF or more is needed near the device between VCC and GND when measuring output and transfer
characteristics.
3. IFLH represents the forward current when the output goes from low to high.
4. Device considered a two terminal device; pins 1-4 are shorted together and pins 5-8 are shorted together.
5. For devices with minimum VISO specified at 5000 V rms, in accordance with UL 1577, each optocoupler is proof-tested by
applying an insulation test voltage ≥ 6000 V rms for one second (leakage current detection limit, II-O ≤ 200 µA).
6. The tPLH and tPHL propagation delays are measured from the 50% level of the input pulse to the 50% level of the output pulse.
7. R2 limits the Q1 and Q2 peak currents. For more applications and circuit design information see Application Note “Power
Transistor Gate/Base Drive Optocouplers.”
7