IEC/EN/DIN EN 60747-5-2 Insulation Characteristics[1]
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage d 300 Vrms
for rated mains voltage d 450 Vrms
for rated mains voltage d 600 Vrms
for rated mains voltage d 1000 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b [2]
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
Input to Output Test Voltage, Method a[2]
VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec,
Partial discharge < 5 pC
Highest Allowable Overvoltage(Transient Overvoltage tini = 60 sec)
Safety-limiting values - maximum values allowed in the event of a failure.
Case Temperature
Input Current [3]
Output Power [3]
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
TS
IS, INPUT
PS, OUTPUT
RS
HCPL-7860 HCPL-786J
I - IV
I - III
I - III
I - II
40/85/21
2
891
1670
I - IV
I - IV
I - IV
I - III
40/85/21
2
1230
2306
1425
1968
6000
175
400
600
>109
8000
175
400
600
>109
Unit
Vpeak
Vpeak
Vpeak
Vpeak
°C
mA
mW
:
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must
be ensured by protective circuits within the application. Surface Mount Classifications is Class
A in accordance with CECC00802.
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,
under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a detailed descrip-
tion of Method a and Method b partial discharge test profiles.
3. Refer to the following figure for dependence of PS and IS on ambient temperature.
Insulation and Safety Related Specifications
800
700
P S (mW)
IS (mA)
600
500
400
300
200
100
0
0 25 50 75 100 125 150 175 200
TS - CASE TEMPERATURE - oC
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
Parameter
Minimum External Air Gap
(Clearance)
Symbol
L(101)
DIP-8
7.4
SO-16 Units
8.3
mm
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Minimum External Tracking L(102) 8.0
8.3
mm
Measured from input terminals to output terminals,
(Creepage)
shortest distance path along body.
Minimum Internal Plastic
Gap (Internal Clearance)
0.5
0.5
mm
Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
Tracking Resistance
CTI
>175 >175 V
(Comparative Tracking
Index)
Isolation Group
IIIa
IIIa
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
6