HCPL-060L-500E Datasheet, PDF (6/19 Pages) AVAGO TECHNOLOGIES LIMITED – High Speed LVTTL Compatible 3.3 Volt Optocouplers
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
Description
Symbol
PDIP Option 060 SO-8 Option 060 Unit
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
I – IV
I – IV
I – IV
I – IV
I – III
I – III
Climatic Classification
40/85/21
40/85/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
VIORM
630
567
Vpeak
Input to Output Test Voltage, Method b*
VPR
VIORM x 1.875 = VPR, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
1181
1063
Vpeak
Input to Output Test Voltage, Method a*
VPR
1008
907
VIORM x 1.6 = VPR, Type and Sample Test, tm=10 sec, Partial
discharge < 5 pC
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
VIOTM
6000
6000
Vpeak
Safety-limiting values
– maximum values allowed in the event of a failure.
Case Temperature
TS
175
150
°C
Input Current
IS, INPUT
230
150
mA
Output Power
PS, OUTPUT
600
600
mW
Insulation Resistance at TS, VIO = 500 V
RS
≥109
≥109
W
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
Thermal Derating Curve Figures
HCPL-060L/HCPL-063L
800
700
PS (mW)
IS (mA)
600
500
400
300
200
100
0 0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – C
HCPL-260L/HCPL-263L
800
700
PS (mW)
IS (mA)
600
500
400
300
200
100
0 0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – C
6