English
Language : 

AFBR-703SMZ Datasheet, PDF (6/19 Pages) AVAGO TECHNOLOGIES LIMITED – Typical power dissipation 600mW
Table 1. Regulatory Compliance
Feature
Test Method
Electrostatic Discharge (ESD)
to the Electrical Contacts
MIL-STD-883C
Method 3015.4
Electrostatic Discharge (ESD)
IEC 61000-4-2
to the Duplex LC Receptacle
Life Traffic ESD Immunity
IEC 61000-4-2
Life Traffic ESD Immunity
IEC 61000-4-2
Electromagnetic
Interference (EMI)
FCC Class B
CENELEC EN55022 Class B
(CISPR 22A)
VCCI Class A
RF Immunity
IEC 61000-4-3
Laser Eye Safety and
Equipment Type Testing
BAUART
GEPRU¨ FT
TU¨ V
Rheinland
Product Safety
TYPE
APPROVED
US FDA CDRH AEL Class 1
US21 CFR, Subchapter J per
Paragraphs 1002.10 and 1002.12
(IEC) EN60825-1: 1994 + A11 + A2
(IEC) EN60825-2: 1994 + A1
(IEC) EN60950: 1992 + A1 + A2 + A3
+ A4 + A11
Component Recognition
Underwriters Laboratories and Canadian
Standards Association Joint Component
Recognition for Information Technology
Equipment including Electrical Business
Equipment
RoHS Compliance
RoHS Directive 2002/95/EC and
it’s amendment directives 6/6
Performance
Class 1 (> 2000 Volts)
Typically, no damage occurs with 25 kV when
the duplex LC connector receptacle is
contacted by a Human Body Model probe.
10 contacts of 8 kV on the electrical faceplate
with device inserted into a panel.
Air discharge of 15 kV (min.) contact to
connector without damage.
System margins are dependent on customer
board and chassis design.
Typically shows no measurable effect from a 10
V/m field swept from 80MHz to 1 GHz
CDRH Accession No. 9720151-072
TUV File R 72071411 page 2
UL file E173874
SGS Test Report No. LPC/13392 (AD-1)/07
CTS Ref. CTS/07/3283/Avago
6