English
Language : 

HCPL-T250-360 Datasheet, PDF (5/7 Pages) AVAGO TECHNOLOGIES LIMITED – 1.5 Amp Output Current IGBT Gate Drive Optocoupler
Regulatory Information
The HCPL-T250 has been approved by the following organizations:
UL
Recognized under UL 1577, Component Recognition
Program, File E55361.
CSA
Approved under CSA Component Acceptance Notice
#5, File CA 88324.
IEC/EN/DIN EN 60747-5-2
Approved under:
IEC 60747-5-2:1997 + A1:2002
EN 60747-5-2:2001 + A1:2002
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01.
(Option 060 only)
Insulation and Safety Related
    Parameter
Symbol Value Units        Conditions
Minimum External Air Gap
L(101) 7.1 mm Measured from input terminals to
(Clearance) output terminals, shortest distance through
air.
Minimum External Tracking
L(102) 7.4 mm Measured from input terminals to
(Creepage) output terminals, shortest distance path
along body.
Minimum Internal Plastic Gap
0.08 mm Insulation thickness between emitter
(Internal Clearance) and detector; also known as distance
through insulation
Tracking Resistance
CTI ≥175 Volts DIN IEC 112/VDE 0303 Part 1
(Comparative Tracking Index)
Isolation Group
IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Absolute Maximum Ratings (Compared with HCPL-3120)
HCPL-3120
HCPL-T250
      Parameter
Symbol Units Min.
Max. Min. Max. Note
Operating Temperature
TA
°C - 40
100 - 20
85
“High” Peak Output Current
IOH(PEAK)
A
2.5
1.5
1
“High” Peak Output Current
IOL(PEAK)
A
2.5
1.5
Storage Temperature
TS
°C -55
125 -55 125
Average Input Current
IF(AVG)
mA
25
20
2
Peak Transient Input Current
(<1 µs Pulse Width, 300 pps)
IF(TRAN)
A
1.0
1.0
Reverse Input Voltage
VR
V
5
5
Supply Voltage
(VCC - VEE)
V
0
35
0
35
Output Voltage
VO
V
0
VCC
0
VCC
Output Power Dissipation
PO
mW
250
250 3
Lead Solder Temperature              260°C for 10 sec., 1.6 mm below seating plane
Solder Reflow Temperature Profile            See Package Outline Drawings section
Notes:
1. Maximum pulse width = 10 µs, maximum duty cycle = 0.2%. See HCPL-3120 Applications section for additional details on limiting IOH(PEAK).
2. Derate linearly above 70°C free-air temperature at a rate of 0.3 mA/°C.
3. Derate lineraly above 70°C free-air temperature at a rate of 4.8 mW/°C.