Absolute Maximum Ratings
Description
Storage Temperature, Ambient
Operating Temperature, Ambient[1]
Supply Voltage[2]
Voltage Applied to Input Logic, dp and Enable Pins
Voltage Applied to Blanking Input[2]
Soldering Temperature [1.59 mm (0.063 inch) Below Body]
  Solder Dipping, max. 5 Seconds
Wave Soldering, max. 3 Seconds
Symbol
Min.
Max.
Unit
TS
-65
+100
°C
TA
-55
+85
°C
VCC
-0.5
+7.0
V
VI, VDP , VE
-0.5
VCC
V
VB
-0.5
VCC
V
260
°C
250
°C
Recommended Operating Conditions
Description
Supply Voltage[2]
Operating Temperature, Ambient[1]
Enable Pulse Width
Time Data Must Be Held Before Positive Transition of Enable Line
Time Data Must Be Held After Positive Transition of Enable Line
Enable Pulse Rise Time
Symbol
VCC
TA
tW
tSETUP
tHOLD
tTLH
Min.
Nom.
Max. Unit
4.5
5.0
5.5
V
-55
+85 °C
100
nsec
50
nsec
50
nsec
1.0
msec
Optical Characteristics at TA = 25°C, VCC = 5.0 V
Device
Description
HDSP-0760
Luminous Intensity per LED (Digit Average)[3,4]
Series
Peak Wavelength
Dominant Wavelength[5]
HDSP-0770
Luminous Intensity per LED (Digit Average)[3,4]
Series
Peak Wavelength
Dominant Wavelength[5]
HDSP-0860
Luminous Intensity per LED (Digit Average)[3,4]
Series
Peak Wavelength
Dominant Wavelength[5,6]
HDSP-0960
Luminous Intensity per LED (Digit Average)[3,4]
Series
Peak Wavelength
Dominant Wavelength[5,6]
Symbol
IV
lPEAK
ld
IV
lPEAK
ld
IV
lPEAK
ld
IV
lPEAK
ld
Min.
Typ. Max. Unit
65
140
µcd
635
nm
626
nm
260
620
µcd
635
nm
626
nm
215
490
µcd
583
nm
585
nm
298
1100
µcd
568
nm
574
nm
Notes:
1. The nominal thermal resistance of a display mounted in a socket that is soldered onto a printed circuit board is RqJA = 50°C/W/device. The
device package thermal resistance is RqJ-PIN = 15°C/W/device. The thermal resistance device pin-to-ambient through the PC board should not
exceed 35°C/W/device for operation at TA = +85°C.
2. Voltage values are with respect to device ground, pin 6.
3. These displays are categorized for luminous intensity with the intensity category designated by a letter code located on the back of the display
package. Case temperature of the device immediately prior to the light measurement is equal to 25°C.