English
Language : 

HCPL-314J-000E Datasheet, PDF (4/15 Pages) AVAGO TECHNOLOGIES LIMITED – 0.4 Amp Output Current IGBT Gate Drive Optocoupler
IEC/EN/DIN EN 60747-5-2 Insulation Characteristics
Description
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
Pollution Degree (DIN VDE 0110/1.89)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875=VPR, 100% Production Test with
tm=1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM x 1.5=VPR, Type and Sample Test,
tm=60 sec, Partial discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage tini = 10 sec)
Safety-limiting values
- maximum values allowed in the event of a failure.
Case Temperature
Input Current**
Output Power**
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VIOTM
Characteristic
I - IV
I - IV
I - III
55/100/21
2
891
1670
1336
6000
Unit
Vpeak
Vpeak
Vpeak
Vpeak
TS
175
°C
IS,INPUT
400
mA
PS, OUTPUT
1200
mW
RS
>109
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulationssection, IEC/
EN/DIN EN 60747-5-2, for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of PS and IS on ambient temperature.
800
700
PS (mW)
IS (mA)
600
500
400
300
200
100
0
0 25 50 75 100 125 150 175 200
TS – CASE TEMPERATURE – °C
HCPL-J314
4