ACPL-W341-000E Datasheet, PDF (4/19 Pages) AVAGO TECHNOLOGIES LIMITED – 3.0 Amp Output Current IGBT Gate Drive Optocoupler
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-P341/W341 is approved by the following organizations:
UL
Recognized under UL 1577, component recognition program up to VISO = 3750 VRMS (ACPL-P341) and VISO = 5000 VRMS
(ACPL-W341) expected prior to product release.
CSA
CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-2 (Option 060 Only)
Maximum Working Insulation Voltage VIORM = 891 Vpeak (ACPL-P341) and VIORM = 1140 Vpeak (ACPL-W341)
Table 1. IEC/EN/DIN EN 60747-5-2 Insulation Characteristics* (Option 060 – Under Evaluation)
Description
ACPL-P341
ACPL-W341
Symbol
Option 060
Option 060
Unit
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
for rated mains voltage ≤ 600 Vrms
for rated mains voltage ≤ 1000 Vrms
I – IV
I – IV
I – IV
I – IV
I – III
I – IV
I – III
I – IV
I – III
Climatic Classification
55/100/21
55/100/21
Pollution Degree (DIN VDE 0110/1.89)
2
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,
Partial discharge < 5 pC
VIORM
VPR
891
1671
1140
2137
Vpeak
Vpeak
Input to Output Test Voltage, Method a*
VIORM x 1.6 = VPR, Type and Sample Test, tm = 10 sec,
Partial discharge < 5 pC
VPR
1426
1824
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
Safety-limiting values – maximum values allowed in the event
of a failure.
Case Temperature
Input Current
Output Power
VIOTM
TS
IS, INPUT
PS, OUTPUT
6000
175
230
600
8000
175
230
600
Vpeak
°C
mA
mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109

* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802.
4