ACPL-H342-000E Datasheet, PDF (4/19 Pages) AVAGO TECHNOLOGIES LIMITED – 2.5 Amp Output Current IGBT Gate Drive Optocoupler
Recommended Pb-Free IR Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non- Halide Flux should be used.
Regulatory Information
The ACPL-H342 / ACPL-K342 is approved by the following organizations:
UL
Recognized under UL 1577, component recognition program up to VISO = 3750 VRMS (ACPL-H342) and VISO = 5000 VRMS
(ACPL-K342), File 55361
CSA
CSA Component Acceptance Notice #5, File CA 88324
IEC/EN/DIN EN 60747-5-5 (ACPL-H342/K342 Option 060 Only)
Maximum Working Insulation Voltage Viorm = 891Vpeak (ACPL-H342) and Viorm = 1140 Vpeak(ACPL-K342)
Table 1. IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (ACPL-H342 / ACPL-K342 Option 060)
Description
Symbol
ACPL-H342 ACPL-K342
Option 060 Option 060 Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 450 Vrms
I – IV
I – IV
I – IV
I – IV
I – III
I – IV
for rated mains voltage ≤ 600 Vrms
I – III
I – IV
for rated mains voltage ≤ 1000 Vrms
Climatic Classification
I – III
40/105/21 40/105/21
Pollution Degree (DIN VDE 0110/39)
2
2
Maximum Working Insulation Voltage
VIORM
891
1140
Vpeak
Input to Output Test Voltage, Method b*
VPR
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
1671
2137
Vpeak
Input to Output Test Voltage, Method a*
VPR
VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
1426
1824
Vpeak
Highest Allowable Overvoltage*
(Transient Overvoltage tini = 60 sec)
VIOTM
6000
8000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature
Input Current
Output Power
TS
175
IS, INPUT
230
PS, OUTPUT
600
175 °C
230 mA
600 mW
Insulation Resistance at TS, VIO = 500 V
RS
>109
>109 W
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/
DIN EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
Note:
These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be ensured by
means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802.
4