ACPL-312U-000E Datasheet, PDF (4/17 Pages) AVAGO TECHNOLOGIES LIMITED – 2.0 A minimum peak output current
Insulation and Safety Related Specifications
Parameter
Symbol
Minimum External Air Gap
(Clearance)
L(101)
Minimum External Tracking L(102)
(Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
(DIN VDE0109)
Value
7.1
7.4
0.08
>175
IIIa
Units
mm
mm
mm
Volts
Conditions
Measured from input terminals to output terminals, shortest
distance through air.
Measured from input terminals to output terminals, shortest
distance path along body.
Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110)
All Avago data sheets report the creepage and clearance inherent to the optocoupler component itself. These dimen-
sions are needed as a starting point for the equipment designer when determining the circuit insulation requirements.
However, once mounted on a printed circuit board, minimum creepage and clearance requirements must be met as
specified for individual equipment standards. For creepage, the shortest distance path along the surface of a printed
circuit board between the solder fillets of the input and output leads must be considered. There are recommended
techniques such as grooves and ribs which may be used on a printed circuit board to achieve desired creepage and
clearances. Creepage and clearance distances will also change depending on factors such as pollution degree and in-
sulation level.
IEC/EN/DIN EN 60747-5-5 Insulation Related Characteristics[1]
Description
Symbol
ACPL-312U
Units
Installation classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤150 V rms
I-IV
for rated mains voltage ≤300 V rms
I-IV
for rated mains voltage ≤450 V rms
I-III
for rated mains voltage ≤600 V rms
for rated mains voltage ≤1000 V rms
Climatic Classification
55/125/21
Pollution Degree (DIN VDE 0110/1.89)
2
Maximum Working Insulation Voltage
VIORM
630
VPEAK
Input to Output Test Voltage, Method b
VIORM x 1.875 = VPR, 100% Production
Test tm = 1 sec, Partial Discharge < 5 pC
VPR
1181
VPEAK
Input to Output Test Voltage, Method a
VIORM x 1.6 = VPR, 100% Type and Sample Test
tm = 10 sec, Partial Discharge < 5 pC
VPR
1008
VPEAK
Highest Allowable Overvoltage
(Transient Overvoltage, tini = 60 sec)
VIOTM
6000
VPEAK
Safety Limiting Values
(Maximum values allowed in the event of a failure,
also see Thermal Derating curve, Figure 11.)
Case Temperature
Input Current
Output Power
Ts
175
°C
Is, INPUT
230
mA
Ps,OUTPUT
600
mW
Insulation Resistance at TS, V10 = 500 V
RIO
≥109
Ω
Notes:
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits within the
application.