Absolute Maximum Ratings
Subjecting the part to stresses beyond those listed under this section may cause permanent damage to the device.
These are stress ratings only and do not imply that the device functions beyond these ratings. Exposure to the
extremes of these conditions for extended periods may affect device reliability.
Parameter
Symbol
Min.
Max.
Units
Notes
Storage Temperature
TS
-40
Operating Temperature
TA
0
Supply voltage (Detector)
VCC
-0.5
Output Voltage
Va , Vb
-0.5
Soldering Temperature
85
°C
60
°C
7
V
VCC + 0.4
V
260
°C
t ≤ 7 sec
DC Forward current (LED)
ILED
Reverse Voltage
VR
50
mA
VF < 1.8V
5
V
IR = 100uA
Recommended Operating Conditions
Parameter
Operating Temperature
Supply Voltage (Detector)
Output Frequency
DC Forward Current (LED)
Symbol
Min.
Typ.
Max.
Units
Notes
T
0
25
60
°C
VCC
3.15
3.3
3.45
V
Ripple < 100mVpp
f
8
40
KHz
(Velocity (rpm) x N)/60
ILED
26
mA
Electrical Characteristics
Electrical Characteristics over Recommended Operating Range, typically at 25°C
Parameter
Symbol
Min.
Typ.
Max.
Units
Supply Current (Detector)
ICC
5
8
mA
LED Forward Voltage
VF
1.3 (turn on) 1.44
1.54
V
1.5 (operate)
Notes
Typical If = 24mA
Encoding Characteristics
Parameter
Symbol
Min (b)
Max (b)
Units
State width error
DS
-40
+40
°e
Pulse width error
DP
-40
+40
°e
Peak to Peak voltage
VppA
1
3
V
VppB
Analog offset voltage
Voffset A
-150
150
mV
Voffset B
Notes:
(a) Obtained at typical conditions specified in “Recommended Operating Conditions” and nominal mounting position (Radial, Tangential, Gap) of
(0,0, 0)
(b) Obtained over the whole “Recommended Operating Conditions” and “Part Mounting Tolerances”