ACPL-M62L Datasheet, PDF (3/9 Pages) AVAGO TECHNOLOGIES LIMITED – SO-5 package
Solder Reflow Profile
Recommended reflow condition as per JEDEC Standard, J-STD-020 (latest revision). Non-Halide Flux should be used.
Regulatory Information
ACPL-M62L is pending approval by the following organizations:
UL
UL 1577, component recognition
program up to VISO = 3750 VRMS File
E55361.
CSA
Approved under CSA Component
Acceptance Notice #5, File CA 88324.
IEC/EN/DIN EN 60747-5-5
(Option 060E only)
Insulation and Safety Related Specifications
Parameter
Minimum External Air Gap
(External Clearance)
Minimum External Tracking
(External Creepage)
Minimum Internal Plastic Gap
(Internal Clearance)
Tracking Resistance
(Comparative Tracking Index)
Isolation Group
Symbol
L(101)
L(102)
CTI
ACPL-M62L Units
5
mm
5
mm
0.08
mm
175
V
Conditions
Measured from input terminals to output terminals,
shortest distance through air.
Measured from input terminals to output terminals,
shortest distance path along body.
Through insulation distance conductor to conductor, usually the
straight line distance thickness between the emitter and detector.
DIN IEC 112/VDE 0303 Part 1
IIIa
Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060E)
Description
Symbol Characteristic Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage ≤ 150 Vrms
for rated mains voltage ≤ 300 Vrms
for rated mains voltage ≤ 600 Vrms
Climatic Classification
I – IV
I – IV
I – III
40/105/21
Pollution Degree (DIN VDE 0110/39)
2
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b*
VIORM × 1.875=VPR, 100% Production Test with tm=1 sec, Partial discharge < 5 pC
Input to Output Test Voltage, Method a*
VIORM × 1.6=VPR, Type and Sample Test, tm=10 sec, Partial discharge < 5 pC
VIORM
VPR
VPR
567
1063
907
Vpeak
Vpeak
Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage tini = 60 sec)
VIOTM
6000
Vpeak
Safety-limiting values – maximum values allowed in the event of a failure
Case Temperature
Input Current
Output Power
Insulation Resistance at TS, VIO = 500 V
TS
150
°C
IS, INPUT 150
mA
PS, OUTPUT 600
mW
RS
>109
Ω
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/EN/DIN
EN 60747-5-5) for a detailed description of Method a and Method b partial discharge test profiles.
3