ELECTRICAL SPECIFICATIONS
Table 1. Absolute Minimum and Maximum Ratings
Parameter
Specifications
Description
Min.
Max.
Unit
Supply Voltage
Vdd
6
V
RF Input Power
RF
0
dBm
MSL
MSL2
Channel Temperature
150
°C
Storage Temperature
-45
150
°C
Comments
Table 2. Recommended Operating Range
Parameter
Description
Pin
Supply Voltage
Vd1
Frequency Range
RF
LO
IF
LO Power
Bias Current
Thermal Resistance, ch-b
Case Temperature
ESD Human Body Model
Machine Model
Specifications
Min.
Typical
3
37
17
DC
15
97
36.7
-40
200
40
Max.
4
43.5
23.25
3
17
+85
Unit
V
GHz
dBm
mA
°C/W
°C
V
V
Comments
Table 3. RF Electrical Characteristics
All data measured on a Taconic RF-35A2 demo board at Vdd = 3 V, TA = 25° C, IF = 1 GHz, LO = 17 dBm, Lower Side Band
(RF + IF = 2*LO) and 50  at all ports, unless otherwise specified.
Performance
Parameter
RF Return Loss
Min.
Typical Max.
Unit Comments
-12
dB
Conversion Gain
RF = 40.5 GHz
10.5
12.1
dB
RF = 42.0 GHz
11.8
RF = 43.5 GHz
12.6
Noise Figure
RF = 40.5 GHz
4.8
6.0
dB
RF = 42.0 GHz
4.7
RF = 43.5 GHz
5
Input IP3
RF = 40.5 GHz
-9
-4.3
RF = 42.0 GHz
-9
-5.8
dBm RF power = -30 dBm/tone,
with f = 10 MHz
RF = 43.5 GHz
-10
-8.7
C/I (IF/2 Suppression)
54
dBc RF Power = -30 dBm
Image Rejection Ratio
RF = 40.5 GHz
12.5
17.2
dB
RF = 42.0 GHz
19.5
RF = 43.5 GHz
20.2
LO Return Loss
-12
dB
LO power = 17 dBm
IF Return Loss
-12
dB
LO power = 17 dBm
Note: Conversion Gain, Noise Figure, Input IP3 and Image Rejection Ratio measurement accuracy is subjected to the tolerance of ± 0.2 dB, ± 0.2 dB,
± 0.2 dBm & ± 0.5 dB respectively.